Battery was removed/battery is fully drained

Once a unit is deactivated,you'll be notified as follows:

In Status → Alerts screen (see

Monitoring Alerts

)

In Status → WGT Map screen, the µWNR is colored in gray (see

Monitoring Station

Equipment

)

The µWNR LED indicator blinks three times when the unit is swayed

7.5.2. Reactivation Methods

There are three ways to reactivate µWNR units:

Using the Station Manager Tag:

1.

Attach the Station Manager Tag to the deactivated unit

2.

Tilt the unit to ensure it wakes up. The LED indicates that the unit is blocked, blinking three times

3.

The Station Manager Tag reactivates the unit. The unit becomes operational and the LED blinks
twice (as it is reactivated and the tag was recognized)

Sending a reactivation command from the

Setup Site

. See

Reactivating WNR Units via

Setup Site

Note: When reactivating the µWNR unit from the Setup Site, the unit becomes fully
functional after next fueling. Simulate refueling (tilt the unit and attach to a Fuel Ring) to
apply reactivation.

Reprogramming the µWNR (setting

Station ID

,

Pump#

,

Nozzle#

anew) using the Wireless

Vehicle Programmer or the Wireless Nozzle Reader Programmer. See

Programming WNR