beautypg.com

Wireless gateway troubleshooting, Table 9-1 - wireless gateway troubleshooting – Gasboy Fuel Point PLUS Station User Manual

Page 105

background image

Fuel Point PLUS Station Equipment Manual

105

6.

Replace the gasket on the µWNR assembly lid:

a.

Remove the two washers

b.

Replace the old gasket with the new one provided with the batteries

c.

Replace the two washers

7.

Replace the lid and secure it with the two Phillips screws

8.

Verify that the indication LED blinks when the unit is tilted

9.

Insert the µWNR assembly back into place, then close the back clamp and secure it with the two
Allen screws

9.4. Wireless Gateway Troubleshooting

Table 9-1

provides troubleshooting guidelines intended to assist the technician in solving common issues

related to Wireless Gateway units

Symptom

Probable Cause

Corrective Action

LEDs are OFF

No AC power input

1.

Verify that the AC power cord is correctly plugged in to
both the AC-output wall outlet and in to the AC-input

2.

Verify that the power socket you are plugged into is in
working condition

No DC power output

1.

Verify that the DC power supply cable is not
damaged. If, yes replace the cable.

2.

Connect the power supply to a different power source
with a new power cord. If the problem persists, the
power supply is the source of the problem. Replace
the power supply with a spare

Communication
LEDs are OFF

Damaged CAT-5E cable

Replace LAN cable

Defective LAN switch

Replace LAN switch

Defective LAN connector in Sta-
tion Controller

Repair/replace Station Controller

Incorrect Master Wireless Gate-
way-Station Controller com-
munication channel settings

Review the settings to ensure both Master Wireless Gateway
and Station Controller match

No communication to
µWNR

Incorrect µWNR settings

Verify that µWNR settings (Station ID, Pump# and Nozzle#
match Master Wireless Gateway settings

Defective µWNR unit

Replace µWNR

Incorrect date and
time in logs after
power failure

Internal battery is drained

Replace Wireless Gateway internal battery

Table 9-1 - Wireless Gateway Troubleshooting