8. TROUBLESHOOTING
Table 3 provides troubleshooting guidelines intended to assist the technician in solving common issues related to µNR units
Table 3. µNR Troubleshooting
Symptom
Probable Cause
Corrective Action
LED does not blink
when the unit is tilted
Defective µNR
Replace µNR unit
Drained battery
Replace battery
LED does not blink
twice when attached
to a FuelOpass
µNR was removed during refueling
and then inserted into another
vehicle's fuel filler
Resume refueling the first vehicle before
reuse
µNR is disconnected from µNR
assembly
Replace µNR unit
Drained battery
Replace battery
Defective FuelOpass
Verify that the FuelOpass is valid and
readable
Reprogram/replace FuelOpass
LED blinks twice but
fueling does not start
FuelOpass is restricted
Verify that the vehicle is allowed to refuel
according to rules/restrictions
Defective FuelOpass
Verify that the FuelOpass is valid and
readable
Reprogram/replace FuelOpass
LED blinks three
times
µNR is deactivated
Reactivate the unit with Station Manager Tag,
WP/NR-P or MWGT Site