8. TROUBLESHOOTING

Table 3 provides troubleshooting guidelines intended to assist the technician in solving common issues related to µNR units

Table 3. µNR Troubleshooting

Symptom

Probable Cause

Corrective Action

LED does not blink

when the unit is tilted

Defective µNR

Replace µNR unit

Drained battery

Replace battery

LED does not blink

twice when attached

to a FuelOpass

µNR was removed during refueling

and then inserted into another

vehicle's fuel filler

Resume refueling the first vehicle before

reuse

µNR is disconnected from µNR

assembly

Replace µNR unit

Drained battery

Replace battery

Defective FuelOpass

Verify that the FuelOpass is valid and

readable

Reprogram/replace FuelOpass

LED blinks twice but

fueling does not start

FuelOpass is restricted

Verify that the vehicle is allowed to refuel

according to rules/restrictions

Defective FuelOpass

Verify that the FuelOpass is valid and

readable

Reprogram/replace FuelOpass

LED blinks three

times

µNR is deactivated

Reactivate the unit with Station Manager Tag,

WP/NR-P or MWGT Site