Specifications, Installation kits – Gasboy Fuel Point PLUS Station User Manual
Page 125
3. SPECIFICATIONS
The following table lists the physical and electrical specifications of the µWNR-
B:
Table 1. µWNR-B Specifications
Parameter
Description
Supply
Voltage:
P/N 812539200 (x2)
Battery replacement should be
performed only by authorized service
personnel
Power
Consumption:
Active mode: 25mA typical. Standby
mode: 20µA
Battery Life
Span
2 to 3 years typical (typical activity:
~50 fuelling per day per nozzle)
Operating
Temperature:
-40
to +60
C
Storage
Temperature:
-40
to +60
C
Dimensions
(HxWxD):
µNR Assembly: 27.2x39.3x44.2mm
NR-B Back Clamp: 106x56.9x72.2mm
Communication
Interface:
1. RF communication method to
WGT:
Frequency: 2.405-2.480 GHz
Typical transmission power:
3dbm (2mW)
2. RFID communication method
with FuelOpass:
Frequency: 119-135 kHz
Storage
1 year
4. INSTALLATION KITS
Table 2 below lists the components included in the different installation kits,
specifically designed for several fuelling nozzle models.
* See paragraph 5.2 for a description of additional component added to µWNR-T
installation kits.
** Flexible Conduit P/N 815900209 (7cm) is provided for Healy 600/700/800/900
models, while P/N 815900204 (0.5m) is provided for Healy 400 only.
Statement for North America:
This reader is suitable for use with the following Hose Nozzle Valves as
indicated in Rows 1, 3, 4, 6. 7 in Table 2. Other Hose Nozzle Valves were not
evaluated for use with this product, including those indicated in Rows 2, 5, 8
in Table 2.