Gasboy Fuel Point PLUS Station User Manual
Page 117
5.1. Installation Highlights
5.1.1. OPW 11 A/B
In the 11A model, the spout retaining screw
used to secure the mechanical fitting is located
on the bottom side of nozzle. In the 11B
model, it is located on the top side (see Figure
3).
Figure 3. Releasing the Spout Retaining Screw
11A (left) & 11B (right)
When installing µWNR-F on unleaded
models, slide the decorative ring over the spout
and press firmly into place (see Figure 4)
Figure 4. Placing the Decorative Ring
5.1.2. ZVA SL 1 /DEF & ZVA SL 2
VR/ZVA 25
To install the mechanical fitting, proceed as
follows:
1. Remove the plastic cover
2. Unscrew the hand guard male-female
screw
3. Place the mechanical fitting on the nozzle,
aligning the mounting holes with the
screw hole
4. Secure the mechanical fitting with the
original female screw and the 16mm
Phillips screw provided in the kit
Figure 5. Securing the Mechanical Fitting
5. Cut a small notch in the plastic cover to
allow the mechanical fitting mounting tab
to come out and replace the plastic cover
Figure 6. Cutting the Plastic Cover
Figure 7. Replacing the Plastic Cover
When installing µWNR-F on SL 2 VR
models
slide the decorative ring over the spout and
press firmly into place (see Figure 4)
When installing µWNR-F on ZVA 25 models,
place the Removal Protection Cover on the top
mounting screw
5.1.2. Husky X
To install the mechanical fitting (see Figure 8),
proceed as follows:
1. Remove the spout lock nut and spout
2. Slide the mechanical fitting over the
nozzle near spout end