106

Fuel Point PLUS Station Equipment Manual

9.5. µWNR Troubleshooting

Table 9-2

provides troubleshooting guidelines intended to assist the technician in solving common issues

related to µWNR units

Symptom

Probable Cause

Corrective Action

LED does not blink
when the unit is
titled

Defective µWNR

Replace µWNR unit

Drained battery

Replace battery

LED does not blink
twice when attached
to a Fuel Ring

µWNR was removed during
refueling and then inserted into
another vehicle's fuel filler

Resume refueling the first vehicle before reuse

µWNR is disconnected from
µWNR assembly

Replace µWNR unit

Drained battery

Replace battery

Defective Fuel Ring

1.

Verify that the Fuel Ring is valid and readable

2.

Reprogram/replace Fuel Ring

LED blinks twice but
fueling does not
start

Fuel Ring is restricted

Verify that the vehicle is allowed to refuel according to
rules/restrictions applied

Defective Fuel Ring

1.

Verify that the Fuel Ring is valid and readable

2.

Reprogram/replace Fuel Ring

LED blinks three
times

µWNR is deactivated

Reactivate the unit. See

Reactivating µWNR Units

Table 9-2 - µWNR Troubleshooting