Μwnr troubleshooting, Table 9-2 - µwnr troubleshooting – Gasboy Fuel Point PLUS Station User Manual
Page 106
106
Fuel Point PLUS Station Equipment Manual
9.5. µWNR Troubleshooting
provides troubleshooting guidelines intended to assist the technician in solving common issues
related to µWNR units
Symptom
Probable Cause
Corrective Action
LED does not blink
when the unit is
titled
Defective µWNR
Replace µWNR unit
Drained battery
Replace battery
LED does not blink
twice when attached
to a Fuel Ring
µWNR was removed during
refueling and then inserted into
another vehicle's fuel filler
Resume refueling the first vehicle before reuse
µWNR is disconnected from
µWNR assembly
Replace µWNR unit
Drained battery
Replace battery
Defective Fuel Ring
1.
Verify that the Fuel Ring is valid and readable
2.
Reprogram/replace Fuel Ring
LED blinks twice but
fueling does not
start
Fuel Ring is restricted
Verify that the vehicle is allowed to refuel according to
rules/restrictions applied
Defective Fuel Ring
1.
Verify that the Fuel Ring is valid and readable
2.
Reprogram/replace Fuel Ring
LED blinks three
times
µWNR is deactivated
Reactivate the unit. See
Table 9-2 - µWNR Troubleshooting