Fuel Point PLUS Station Equipment Manual
Step
Display
Description
1
The main menu is displayed. Select the T48 Functions option
2
Select the Prog VIS NR option
3
Enter the Station ID as set in Master Wireless Gateway
4
Enter the number of the pump as set in Master Wireless Gateway
5
Enter the number of the nozzle on which the unit is installed as set in
Master Wireless Gateway
6
Verify that all the parameters are correct. Sway the µWNR (or press the
µWNR-T activation switch), attach the unit to the programming coil and
press SEND
7
Wait a few seconds
8
A success message is displayed. Press A to return to the main menu
Table 7-2 - µWNRProgramming Sequence - Retail Stations
7.5. Reactivating µWNR Units
The µWNR units include a tamper resistant feature that prevents unauthorized removal, deactivating the
unit whenever an attempt is made.
7.5.1. Causes Of Deactivation
There are two possible triggers that can cause the units to enter into deactivation mode:
An attempt to remove µWNR-F from the nozzle occurred: Removal Protection ring was taken
off, disconnecting activation wires