beautypg.com

Figure 6-30 - status - µwnr reactivation, Table 6-12 - reactivation table fields, Figure 6-30 – Gasboy Fuel Point PLUS Station User Manual

Page 76: Table 6-12

background image

76

Fuel Point PLUS Station Equipment Manual

Figure 6-30 - Status - µWNR Reactivation

Do one of the following:

To reactivate a specific µWNR: In the Reactivation column, select the checkbox in the

corresponding row and then click

Submit

To reactivate all deactivated units: Click

Select All

and then click

Submit

Note: When reactivating the µWNR unit from the Setup Site, the unit becomes fully
functional after next fueling. Simulate refueling (tilt the unit and attach to a Fuel Ring) to
apply reactivation.

Field

Description

Reactivation

Select this checkbox to reactivate the unit

Group#

Unit's group (for communication with Station Controller)

Channel#

Logical channel for communication with the controller

Pump#

Number of the pump to which the unit is associated

Nozzle#

Number of the nozzle on which the unit is installed

Wireless Gateway
Address

Logical address of the Wireless Gateway to which the µWNR is routed

Location

Wireless Gateway's location

Table 6-12 - Reactivation Table Fields