Importing setup, Figure 6-8 - submit button warning, Table 6-3 - minimal setup parameters – Gasboy Fuel Point PLUS Station User Manual
Page 55
Fuel Point PLUS Station Equipment Manual
55
Figure 6-8 - Submit Button Warning
Parameter
Description
Station ID
ID number of the station. Must be identical for Master Wireless Gateway and all Wireless Gateway units
Logical Address
Unique logical address that identifies the unit within the network. Master Wireless Gateway default is 1
and cannot be changed, and so this field is disabled
Location
Descriptive free text to easily identify the unit
Wireless Gate-
way Type
Select Default for Master Wireless Gateway
Select Manually for a Wireless Gateway unit
Wireless Active
Channels
Wireless channels for network communication between the units. Select two nonconsecutive channels
Setup Source
Enables importing a setup file
Select From Setup File to import an .XML file (see below)
Select Manually to manually set the network
Submit
Saves the settings of the current tab. To apply the changes, see
Restore Factory
Setup
Restores factory default settings by selecting the default version from the drop-down list (WW, unless
otherwise specified by Professional Services) and then clicking on the Restore Factory Setup button
Table 6-3 - Minimal Setup Parameters
6.5.1.1. Importing Setup
Once you have setup a network, you can save the .XML setup file instead of manually setting up the
Wireless Network. See
Then you may import those settings and override the parameters as needed (i.e. Wireless Channels ,
µWNR settings, etc.) to match the configuration of the station.
1.
Select the
From Setup File
radio button
2.
Click
Browse
. A file selection dialog appears
3.
Select the .XML file and click
Open
4.
Click
Upload
5.
Click
Submit
6.
Override the network settings as needed
7.
Apply the changes. See