beautypg.com

Rebuilding tables, Exporting network settings – Gasboy Fuel Point PLUS Station User Manual

Page 83

background image

Fuel Point PLUS Station Equipment Manual

83

Update at Date & Time

: The update is executed at a specific time. When this option

is selected, Update Time fields are displayed. Enter the update

Date

and

Time

Update at Admin Command

: The update is executed only after all the Wireless

Gateway units received the files. When this option is selected, additional options
appear:

Automatic

: When this option is selected, the network is automatically reset

Manual

: (default). Reset is manually initiated by the user by clicking

Send

Update without Reset

: Update is executed immediately, but new setup takes effect

after the network is manually reset. See

Saving Setup

6.

Click

Distribute Setup Files

Best Practice: It is highly recommended to use Update at Admin Command - Manual.
Verify that the status off all the units in the table is Pending and it remains so for about 10
minutes and then reset the network (by clicking Send). Please remind that the network
can only be reset when the station is idle (there is no refueling).

Column

Description

Select

Selects the unit

Logical Num

Unit's logical address

Wireless Gateway Type

Unit type: Master Wireless Gateway (Master Wireless Gateway) or Wireless Gateway

Location

Wireless Gateway's location

Setup File

Selects the .XML setup file

Status

Setup update status: In Progress Pending Complete

Table 6-15 - Wireless Gateway Station Map Table Parameters

6.8.3.1. Rebuilding Tables

See

Rebuilding Tables

6.8.4. Exporting Network Settings

You can connect to MWGT and export setup files from Master Wireless Gateway and Wireless Gateway
units to reuse in other similar stations. See

Importing Network Settings

.(See

Figure 6-38

,

Table 6-16

).