Approved location, Installation instructions, Figure 5-1 - approved location – Gasboy Fuel Point PLUS Station User Manual
Page 42

42
Fuel Point PLUS Station Equipment Manual
5.3. Approved Location
Due to safety requirements, the Wireless Gateway outdoor must be installed at non-hazardous area/non-
classified area (see
):
Above 18” (0.5 meter) from the Isle floor
At least 18” (0.5 meter) away from the dispenser
18"/0.45m
18"/0.45m
18"/0.45m
Wireless
Gateway
Outdoor
Class I Div 2 Safety Area
Figure 5-1 - Approved Location
5.4. Installation Instructions
1.
Remove the Wireless Gateway front panel
2.
Remove the cable entry knockout plates on the bottom panel:
For Master Wireless Gateway remove two panels (one for LAN and one for Power
cables)
For Wireless Gateway remove one panel for the Power cable
3.
Place the unit vertically with cable entry openings facing down
4.
Secure the unit to a flat surface, inserting four screws in the mounting openings located at the four
corners of the unit (see
5.
Connect power supply:
For units equipped with integrated P/S: Connect AC P/S to the AC terminal
For units without integrated P/S: connect a 12-28 VDC (stabilized),0.5A power supply
to the Power Connector
Use an external AC to DC or DC to DC switching power supply transformer approved
according to the local regulations. In North America use a AC to DC NEC Class 2 power
supply, low voltage and low current maximum 100 VA even under fault conditions. The
power supply can be installed in the office, in the pedestal, in the tanker truck cabin (DC
to DC power supply) or in a separate box