Figure 8) – Gasboy Fuel Point PLUS Station User Manual
Page 118
3. Replace the spout and tighten the spout
lock firmly
Figure 8. Mechanical Fitting & Spout Adaptor
5.1.4 TATSUNO
To install the mechanical fitting, proceed as
follows:
1. Remove the plastic cover
2. Release the two spout retaining screws
3. Place the Mechanical Fitting on the nozzle near
spout end, aligning the mounting holes with the
screw holes and secure it to the nozzle using the
spout retaining screws
4. Slide the µNR Housing over the spout and install
on the Mechanical Fitting
5.1.5 OPW 7H
To install the mechanical fitting, proceed as
follows:
1. Remove the plastic cover
2. Release the three spout retaining screws
3. Place the Mechanical Fitting on the nozzle near
spout end, aligning the mounting holes with the
screw holes and secure it to the nozzle using the
provided NC10-24x5/8" screws
4. Slide the µNR Housing over the spout and install
on the Mechanical Fitting
Place the Removal Protection Cover on the top
mounting screw
6. POST INSTALLATION
CHECKLIST
The μNR is supplied as ready-for- installation kit.
After assembling and programming the μNR,
switch on the dispenser and please verify that:
1. The pump switches on after the μNR identifies
the FuelOpass
2. Connections are tight and leak free
3. After installation the installer is to verify that the
hose nozzle valve fits correctly into the
dispensing device’s hose nozzle boot.
a) The hose nozzle valve shall be able to be
placed in the hose nozzle boot without falling
out;
b) The hose nozzle valve shall not be allowed to
be placed in the hose nozzle boot without
shutting down the dispenser;
c) The hose nozzle valve shall be able to be
locked in position such that the pump cannot be
started.
If the hose nozzle valve/reader combination does
not fit correctly, then the reader should be
removed and cannot be used with that hose
nozzle valve.
7. MAINTENANCE
7.1. General
The μNR does not require any cleaning or
lubrication.
Inspect regularly for visual damages
7.2. Battery Replacement
The following should be performed by properly
trained personnel.
Warning: to reduce the risk of ignition of a
flammable atmosphere, batteries must only be
changed in an area known to be nonflammable.
1. Remove the three Allen screws that secure the
back and front covers (see Figure 9) and detach
the back cover
Figure 9. Detaching the Back Cover
2. .Pull out the µNozzle Reader assembly carefully,
to avoid damaging the wires (see Figure 10)