3. Replace the spout and tighten the spout

lock firmly

Figure 8. Mechanical Fitting & Spout Adaptor

5.1.4 TATSUNO

To install the mechanical fitting, proceed as

follows:

1. Remove the plastic cover
2. Release the two spout retaining screws
3. Place the Mechanical Fitting on the nozzle near

spout end, aligning the mounting holes with the

screw holes and secure it to the nozzle using the

spout retaining screws

4. Slide the µNR Housing over the spout and install

on the Mechanical Fitting

5.1.5 OPW 7H

To install the mechanical fitting, proceed as

follows:

1. Remove the plastic cover
2. Release the three spout retaining screws
3. Place the Mechanical Fitting on the nozzle near

spout end, aligning the mounting holes with the

screw holes and secure it to the nozzle using the

provided NC10-24x5/8" screws

4. Slide the µNR Housing over the spout and install

on the Mechanical Fitting

Place the Removal Protection Cover on the top

mounting screw

6. POST INSTALLATION
CHECKLIST

The μNR is supplied as ready-for- installation kit.

After assembling and programming the μNR,

switch on the dispenser and please verify that:
1. The pump switches on after the μNR identifies

the FuelOpass

2. Connections are tight and leak free
3. After installation the installer is to verify that the

hose nozzle valve fits correctly into the

dispensing device’s hose nozzle boot.
a) The hose nozzle valve shall be able to be

placed in the hose nozzle boot without falling

out;
b) The hose nozzle valve shall not be allowed to

be placed in the hose nozzle boot without

shutting down the dispenser;
c) The hose nozzle valve shall be able to be

locked in position such that the pump cannot be

started.
If the hose nozzle valve/reader combination does

not fit correctly, then the reader should be

removed and cannot be used with that hose

nozzle valve.

7. MAINTENANCE

7.1. General

The μNR does not require any cleaning or

lubrication.
Inspect regularly for visual damages

7.2. Battery Replacement

The following should be performed by properly

trained personnel.
Warning: to reduce the risk of ignition of a

flammable atmosphere, batteries must only be

changed in an area known to be nonflammable.
1. Remove the three Allen screws that secure the

back and front covers (see Figure 9) and detach

the back cover

Figure 9. Detaching the Back Cover

2. .Pull out the µNozzle Reader assembly carefully,