BINDER CB 60 User Manual
Operating manual, Apt.line™ cb (e6) co, Incubators co
Issue 09/2013
Art. No. 7001-0229
Operating Manual
APT.line™ CB (E6)
CO
2
- Incubators
CO
2
– Incubators with O
2
control
with sterilizable NDIR sensor system for CO
2
and humidity
and microprocessor controller T4.12
Model
Voltage
Equipment
Art. No.
CB 60
230 V
9040-0088, 9140-0088
CB 60-UL
100-120V
9040-0089, 9140-0089
CB 60
230 V
with O
2
control
9040-0090, 9140-0090
CB 60-UL
100-120V
with O
2
control
9040-0091, 9140-0091
CB 160 (E6) 230 V
9040-0092, 9140-0092
CB 160-UL
100-120V
9040-0093, 9140-0093
CB 160 (E6) 230 V
with O
2
control
9040-0094, 9140-0094
CB 160-UL
100-120V
with O
2
control
9040-0095, 9140-0095
CB 160
230 V
with divided glass door
9040-0100, 9140-0100
CB 160-UL
100-120V
with divided glass door
9040-0101, 9140-0101
CB 160
230 V
with O
2
control
with divided glass door
9040-0102, 9140-0102
CB 160-UL
100-120V
with O
2
control
with divided glass door
9040-0103, 9140-0103
CB 220
230 V
9040-0096, 9140-0096
CB 220-UL
100-120V
9040-0097, 9140-0097
CB 220
230 V
with O
2
control
9040-0098, 9140-0098
CB 220-UL
100-120V
with O
2
control
9040-0099, 9140-0099
BINDER GmbH
Address
Post office box 102
D-78502 Tuttlingen
Tel.
+49 7462 2005 0
Fax
+49 7462 2005 100
Internet
http://www.binder-world.com
Service Hotline
+49 7462 2005 555
Service Fax
+49 7462 2005 93 555
Service E-Mail
Service Hotline USA
+1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific
+852 39070500 or +852 39070503
Service Hotline Russia and CIS
+7 495 98815 17
Document Outline
- EG – declaration of conformity
- Product registration
- 1. Safety
- 1.1 Legal considerations
- 1.2 Structure of the safety instructions
- 1.3 Localization / position of safety labels on the unit
- 1.4 Type plate
- 1.5 General safety instructions on installing and operating the CO2 incubator
- 1.6 Precautions when working with gases
- 1.7 Precautions when handling gas cylinders
- 1.8 Intended use
- 2. Unit description
- 3. Completeness of delivery, transportation, storage, and installation
- 4. Installation and connections
- 5. Start up
- 6. Functional overview of the T4.12 chamber controller
- 6.1 Menu structure
- 6.2 Operating modes
- 6.3 Deactivating the O2 control and O2/N2 pressure alarms (unit with O2 control)
- 6.4 Humidity control of the Permadry™ system
- 6.5 Turning on / off the interior socket voltage (with optional interior socket)
- 6.6 Performance during and after power failure
- 6.7 Information
- 7. Setpoint entry
- 8. Key lock
- 9. General controller settings
- 9.1 Setup wizard
- 9.2 Date and time settings
- 9.3 Selecting the menu language of the T4.12 controller
- 9.4 Setting display brightness
- 9.5 Changing the temperature unit
- 9.6 Defining the data recording rate
- 9.7 Factory reset
- 9.8 Network configuration
- 9.9 Display of the network configuration
- 9.10 MAC Address
- 9.11 RS 422 address (with optional RS 422 interface)
- 9.12 Display and entry of the device configuration – for service purpose
- 10. Data transfer via USB interface
- 11. Notifications and Alarms
- 12. Event list
- 13. Graphical display of the measured values
- 14. Temperature safety devices
- 15. Options
- 15.1 Communication software APT-COM™ 3 DataControlSystem (option)
- 15.2 RS 422 interface (option)
- 15.3 Silicone access ports 30 mm / 1.18 in, closable from both sides with silicon plugs (option)
- 15.4 Interior socket 230V (option)
- 15.5 Analog outputs for temperature and CO2 (option)
- 15.6 Access port for extra-low voltage (option)
- 15.7 BINDER Gas Supply Service – External bottle changer for CO2, N2 or O2 (option)
- 15.8 Stands
- 16. Reference measurements
- 17. Avoiding microbial contamination
- 18. Cleaning, decontamination / disinfection, and sterilization
- 19. Maintenance and service
- 20. Disposal
- 21. Troubleshooting
- 22. Technical description
- 22.1 Factory calibration and adjustment
- 22.2 Over current protection
- 22.3 Definition of usable volume
- 22.4 CB technical data
- 22.5 Equipment and Options
- 22.6 Spare parts and accessories
- 22.7 Important conversion data for non-SI units
- 22.8 Conversion table for gas inlet pressures, bar – psi
- 22.9 Dimensions CB 60
- 22.10 Dimensions CB 160
- 22.11 Dimensions CB 220
- 23. Contamination clearance certificate
- Word-Lesezeichen