Page 104/144

Reduce the number of personnel and their movements in the lab by careful positioning all relevant

equipment. For practical reasons, install the CO

2

incubator close to the laminar air flow bench.

Regular microbiological monitoring of the cell culture laboratory.

17.3 Working and behavior in the lab

Sources of contamination are often the laboratory personnel themselves (surface germs, oral flora droplet

transfer) and handling the equipment and cultures. We recommend staff training in aseptic techniques,

laboratory safety and good laboratory practice (GLP).
Examples of general rules to reduce the contamination risks

Reduce hand germ count (wash hands with antimicrobial soap, dry with paper tissues, and rub dry

hands with alcohol-based solution).

Wear appropriate clothing (work coat, shoes, face mask)

Keep as few personnel as possible in the cell culture lab.

Examples of sterile working method

Work "clean-to-dirty", i.e., handle confirmed uncontaminated cells first, unknown or untested cells next,

and lastly, if necessary, cells suspected to be contaminated.

Perform daily microscopic observations of cultures and specific tests for the bacteria and fungi as part

of a controlled routine. Test cultures for sterility before starting work.

Keep working surfaces clean. Immediately wipe spilled liquids with alcohol solutions.

No mouth contact on pipettes.

Never work on top of open sterile containers.

17.4 Chamber design and equipment of the CO

2

incubator

The design concepts behind the CO

2

incubator CB considerably reduce the risk of contamination. Among

them are:
Even surfaces for easy manual cleaning

The inner surfaces are smooth and therefore easy to clean. The inner chamber is deep-drawn from a

single piece, polished (suitable for pharmaceutical work) and has no welds or inaccessible corners.

The hinges and the seal of the inner glass door are glued from the outside, which also aids cleaning of

the inner chamber.

Removable parts for cleaning and autoclaving

The shelves are easily removed without screws. It is possible to autoclave the shelves. But this is

generally not necessary because they can remain inside the incubator during sterilization.

Door gasket

The inner door gasket is removable and autoclavable.

Gas fine filter

The incoming gas used in the operation passes through a fine filter (aseptic filter, filtration efficiency

99.99 %, particle size 0.45 µm) with a high filtration efficiency, which can also filter the smallest

particles.

CO

2

measuring system in the inner chamber

The CO

2

sensor can be hot-air sterilized inside the chamber.

O

2

measuring system in the inner chamber

The O

2

sensor can be hot-air sterilized inside the chamber.