BINDER KBF LQC 240 User Manual
Operating manual, Apt.line™ kbf lqc (e5.3)
Issue 07/2014
Art. No. 7001-0283
Operating Manual
APT.line™ KBF LQC (E5.3)
Constant climate chambers
with ICH compliant illumination and light dose detection
with program control and adjustable light cassettes
Model
Art. No.
KBF LQC 240 (E5.3)
9020-0277, 9120-0277
KBF LQC 720 (E5.3)
9020-0279, 9120-0279
BINDER GmbH
Address
Post office box 102
D-78502 Tuttlingen
Tel.
+49 7462 2005 0
Fax
+49 7462 2005 100
Internet
http://www.binder-world.com
Service Hotline
+49 7462 2005 555
Service Fax
+49 7462 2005 93 555
Service E-Mail
Service Hotline USA
+1 866 885 9794 or +1 631 224 4340 x3
Service Hotline Asia Pacific
+852 390 705 04 or +852 390 705 03
Service Hotline Russia and CIS +7 495 988 15 16
This manual is related to the following products:
Table of contents
Document Outline
- EC – declaration of conformity
- Product registration
- 1. Safety
- 1.1 Legal considerations
- 1.2 Structure of the safety instructions
- 1.3 Localization / position of safety labels on the unit
- 1.4 Type plate
- 1.5 General safety instructions on installing and operating the constant climate chamber
- 1.6 Intended use
- 1.7 Resistance of the humidity sensor against harmful substances
- 2. Unit description
- 3. Completeness of delivery, transportation, storage, and installation
- 4. Installation and connections
- 5. Start up
- 6. Settings of the MB1 controller
- 7. Graphic representation of the historical measurement (chart recorder function)
- 8. Manual Mode
- 9. Function of light measurement, and integration: Light Quantum Control
- 10. Program operation of the temperature, and humidity controller
- 10.1 Overview menu-based program entry
- 10.2 Entry of temperature values and fan speed
- 10.3 Entry of humidity values
- 10.4 Selecting between set-point ramp and set-point step
- 10.5 Program entry as set-point ramp or as set-point step
- 10.6 Advice for the programming of the different temperature or humidity transitions
- 10.7 Repetition of a section or several sections within a program
- 10.8 Performance after power failure in Program Mode
- 10.9 Starting a previously entered program
- 10.10 Deleting a program
- 10.11 Template for temperature profile
- 10.12 Template for humidity profile
- 10.13 Program table template for temperature and fan speed rate
- 10.14 Program table template for humidity
- 11. Temperature safety devices
- 12. Notification and alarm functions
- 13. Humidity system
- 14. Defrosting at refrigerating operation
- 15. ICH compliant illumination according to CPMP/ICH/279/95 (Q1B)
- 16. Characteristic features of the light sensors
- 17. Options
- 17.1 Communication software APT-COM™ 3 DataControlSystem (option)
- 17.2 Interface RS 422 (option)
- 17.3 Data logger kits (option)
- 17.4 Analog outputs for temperature and humidity (option)
- 17.5 Zero-voltage relay alarm outputs for temperature and humidity for alarm transmission (option)
- 17.6 Water protected internal socket (option)
- 17.7 Keyboard locking (option)
- 17.8 Additional flexible Pt 100 temperature sensor (option)
- 17.9 External freshwater and waste-water cans (option)
- 17.10 BINDER Pure Aqua Service (option)
- 18. Maintenance, cleaning, and service
- 19. Disposal
- 20. Troubleshooting
- 21. Technical description
- 22. Contamination clearance certificate
- Word-Lesezeichen
- Leere Seite