Ole_link1, Ole_link2 – BINDER CB 60 User Manual

Page 132

background image

CB (E6) 09/2013

Page 132/144

Unit size

60

160

220

Humidity data
Humidity

% r.H.

90 to 95

90 to 95

90 to 95

O

2

Data

O

2

range

vol.-% O

2

0.2 to 95

0.2 to 95

0.2 to 95

Setting accuracy with inlet pressure 2 bar

vol.-% O

2

0.1

0.1

0.1

Recovery time after door was opened for

30 sec at 1 vol-% O

2

1)

minutes

8

12

18

Recovery time after door was opened for

30 sec at 5 vol-% O

2

1)

minutes

8

12

18

O

2

measurement

ZrO

2

ZrO

2

ZrO

2

Connection hose nozzle DN6 for O

2

/N

2

connection to the unit for hose with internal

diameter

mm / inch

6 / 0.24

6 / 0.24

6 / 0.24

Electrical data CB
IP system of protection acc. to EN 60529

IP

20

20

20

Nominal voltage (±10 %)

V

200-240 1N~ 200-240 1N~ 200-240 1N~

Power frequency

Hz

50/60

50/60

50/60

Nominal power

kW

1.00

1.30

1.50

Energy consumption 2) at 37 °C/ 98.6 °F

Wh/h

80

100

120

Power plug (IEC connector plug)

Shock-proof plug

Installation category acc. to IEC 61010-1

II

II

II

Pollution degree acc. to IEC 61010-1

2

2

2

Unit fuse 4x20mm / semi time-lag (M)

Amp

10

10

10

Electrical data CB-UL (for the USA and Canada)
Nominal voltage (±10 %) 60 Hz / 1N

V

100-120 1N~ 100-120 1N~ 100-120 1N~

Power frequency

Hz

50/60

50/60

50/60

Power plug

NEMA

5-15P

5-20P

5-20P

Nominal power

kW

1.00

1.30

1.50

Installation category acc. to IEC 61010-1

II

II

II

Pollution degree acc. to IEC 61010-1

2

2

2

Unit fuse 6.3 X 32 mm / 250V / super-time-

lag TT

Amp

16 external

16 external

16 external

Additional temperature fuse class 1 (DIN 12880)

internal

internal

internal

Legend:
1) The recovery times of the gas concentrations inside the chamber after the door is opened coincide

with a connection pressure of 2.0 bar / 29 psi. Decreasing supply pressure results in longer recovery

times.

2) Use this value for sizing air condition systems.
All technical data is specified for unloaded units with standard equipment at an ambient temperature of

22 ±3 °C / 71.6 ±5.4 °F and a power supply voltage fluctuation of ±10. The temperature data is

determined in accordance to BINDER factory standard and DIN 12880, observing the recommended wall

clearances of 10 % of the height, width and depth of the inner chamber.
All indications are average values, typical for units produced in series. We reserve the right to

change technical specifications at any time.

This manual is related to the following products: