to 644.53125 MHz ±100 ppm. For 24.24 Gbps variations, you must set the frequency of
clk_ref
either to
390.625 MHz ±100 ppm or to 195.3125 MHz ±100 ppm.
Sync–E IP core variations are duplex IP core variations for which you turn on Enable SyncE support in
the parameter editor. These variations provide separate IP core input reference clock signals for the TX
and RX transceiver PLLs, and provide the RX recovered clock as a top-level output signal.
The Synchronous Ethernet standard, described in the ITU-T G.8261, G.8262, and G.8264 recommenda‐
tions, requires that the TX clock be filtered to maintain synchronization with the RX reference clock
through a sequence of nodes. The expected usage is that user logic drives the
tx_ref_clk
signal with a
filtered version of the RX recovered clock signal, to ensure the receive and transmit functions remain
synchronized.
In a Sync–E IP core, the restrictions apply to each of the
rx_clk_ref
and
tx_clk_ref
input clocks.
The minimum clock frequency for the IP core is 315 MHz. The only exception is the 40GbE lower rate
24.24 Gbps MAC and PHY IP core, which has a minimum clock frequency of 190.90 MHz.
Table 3-16: Clock Inputs
Describes the input clocks that you must provide.
Signal Name
Description
clk_status
A clock for reconfiguration, offset cancellation, and housekeeping
functions. This clock is also used for clocking the control and status
interface. The clock quality and pin chosen are not critical.
clk_status
is
expected to be a 37.5–50 MHz clock on Stratix IV devices and a 100–
125 MHz clock on Stratix V devices.
clk_ref
clk_ref
is the reference clock for the transceiver TX PLL and the RX
CDR PLL. This input signal is not available in Sync–E variations.
The frequency of this input clock must match the value you specify for
PHY reference frequency in the IP core parameter editor.
For the regular 40GbE and 100GbE IP core variations, this clock must
have a frequency of 322.265625 or 644.53125 MHz with a ±100 ppm
accuracy per the IEEE 802.3ba-2010 100G Ethernet Standard.
Despite its apparent availability in the 40-100GbE parameter editor,
CAUI–4 variations do not support the 322 MHz clock frequency. For
these variations, this clock must have a frequency of 644.53125 MHz with
a ±100 ppm accuracy.
For 24.24 Gbps IP core variations, this clock must have a frequency of
390.625 or 195.3125 MHz with a ±100 ppm accuracy.
In addition,
clk_ref
must meet the jitter specification of the IEEE
802.3ba-2010 100G Ethernet Standard.
The PLL and clock generation logic use this reference clock to derive the
transceiver and PCS clocks. The input clock should be a high quality
signal on the appropriate dedicated clock pin.
The PCS clock frequency is 257.8125 MHz for standard variations,
201.416 MHz for CAUI–4 variations, and 156.25 MHz for 24.24 Gbps
variations.
3-52
Clocks
UG-01088
2014.12.15