beautypg.com

Figure d-3, Figure d-4 – Digilent 6003-410-000P-KIT User Manual

Page 103

background image

XUP Virtex-II Pro Development System

www.xilinx.com

103

UG069 (v1.0) March 8, 2005

1-800-255-7778

Processor-Based Tests

R

PC running Hyper Terminal or similar terminal program.One 1.5 Gb/s rated serial
ATA cable

One 1.5 Gb/s rated serial ATA cable

This test begins when the “1” is selected from the Built-In Self-Test Main Menu displayed
on the terminal window. The board should already have a serial ATA cable connected in a
looped back configuration, between serial ATA 0 HOST and serial ATA 1 Target, or
between serial ATA 2 HOST and serial ATA 1 Target.

See

Figure D-3

and

Figure D-4

.

Note:

While either test is running, all three of the MGTs connected to the serial ATA connectors are

active, but the test software is only monitoring one pair at a time. If you select the wrong loop pair to
test, the target can transmit and receive data/frames, but you would be monitoring the wrong loop pair
of transceivers. Thus, the test will fail.

Figure D-3:

Testing the SATA 0 HOST to SATA 1 TARGET Connection

Figure D-4:

Testing the SATA 2 HOST to SATA 1 TARGET Connection