ClearOne Converge 590 User Manual
Page 79

Appendix
85
METER TYPE DEFINITIONS
SERIAL COMMAND ERROR CODES
E
Errrroorr nnuum
mbbeerr
TTeexxtt m
meessssaaggee
E
Exxppllaannaattiioonn//S
Soolluuttiioonn
1
Memory error
The box is out of internal memory.
Power cycle the box.
2
No command found
A command was not found in the string.
3
Unknown command
A command was executed on a different
device type that this box response can
not display. The command dictionary
needs to be updated.
4
Not implemented
The command is not implemented.
5
Argument error
The command had an argument that was
out of range.
6
Unknown command
The command is unknown to this unit.
7
Bad checksum
The binary command’s checksum is
wrong.
8
Camera not responding
A preset or macro failed to program
because it is too large or because its
command list contained an invalid
command.
11
Command too big
The binary command is too large.
Alpha
Numeric
Level position
for Mic Channel
Level position
for Line Inputs
Level position
for Outputs
Level position
for Telco Transmits
Level position
for Telco Receives
A
R
E
T
2
5
6
7
Post Processing
Meter
after Signal
Processing Chain
Level after PEQ
and gain
Level after PEQ
and gain
Level after gain
Level after gain
adjustment
Echo Return Loss
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Echo Return Loss
ERL + ERLE
FIGURE 6.5