beautypg.com

ClearOne Converge 590 User Manual

Page 104

background image

110

Technical Services: 800.283.5936

GHOLD - GATE HOLD TIME ADJUST

This command sekects/reports the setting of the hold time for a microphone input.

A

AR

RG

GU

UM

ME

EN

NTT D

DE

ETTA

AIILLS

S

N

Naam

mee

TTyyppee

S

Siizzee

VVaalluueess

U

Unniittss

Channel

Unsigned Integer

8

See Group and Channels

Group

Unsigned Integer

8

3

Value

Unsigned Float

16

.10 - 8.00

Seconds

(Null returns current hold time)

B

BIIN

NA

AR

RYY FFO

OR

RM

M D

DE

ETTA

AIILLS

S

COMMAND ID:

118

NUMBER OF ARGUMENTS:

1

ARGUMENT FORM:

TTE

EXXTT FFO

OR

RM

M D

DE

ETTA

AIILLS

S

COMMAND FORM:

DEVICE G

GH

HO

OLLD

D [Value]

GMODE - GATING MODE

This command sekects/reports the setting of the gating mode for a microphone input.

A

AR

RG

GU

UM

ME

EN

NTT D

DE

ETTA

AIILLS

S

N

Naam

mee

TTyyppee

S

Siizzee

VVaalluueess

U

Unniittss

Channel

Unsigned Integer

8

See Group and Channels

Group

Unsigned Integer

8

3

Value

Unsigned Integer

16

1 = auto
2 = manual on
3 = manual off
(Null returns the current mode)

B

BIIN

NA

AR

RYY FFO

OR

RM

M D

DE

ETTA

AIILLS

S

COMMAND ID:

108

NUMBER OF ARGUMENTS:

1

ARGUMENT FORM:

TTE

EXXTT FFO

OR

RM

M D

DE

ETTA

AIILLS

S

COMMAND FORM:

DEVICE G

GM

MO

OD

DE

E [Value]