Appendix a: application programmer’s interface
228
APPENDIX A: APPLICATION PROGRAMMER’S INTERFACE
TYPE AND DEVICE IDS
Converge/Converge Pro Device Types and Device IDs by model are as follows:
Model
Device Type
Device ID Range
880
1
0-B
TH20
2
0-F
VH20
E
0-F
840T
3
0-B
8i
A
0-B
880T
D
0-B
880TA
H
0-B
SR 1212
G
0-B
SR 1212A
I
0-B
Beamforming
Mic Array
N
0-F
CONVENTIONS
This guide uses the following typographic conventions to describe Converge/Converge Pro serial command
syntax:
Convention
Description
Parameters enclosed in < > indicate a mandatory parameter
[X]
Parameters enclosed in [ ] indicate an optional parameter
1-8
Parameters separated by a ‘-‘ indicate a range of allowable values
4,7,9
Parameters separated by a ‘,’ indicate a list of allowable values
EREF
Words in UPPERCASE bold indicate command text
Device
Indicates the device type and device number on the Expansion Bus. It is composed
of a device type character and a device ID character.
COMMAND FORM DESCRIPTION
The structure of serial commands is as follows:
#
# indicates the start of a command line, the Carriage Return terminates a command.
NOTE
:
Serial commands can be either UPPERCASE or lowercase. Return values are always in
UPPERCASE. In order for a command to be recognized by the RS-232 serial port, the
command must be terminated by a carriage return.
For example, a command to disable mute for Mic Input 5 on a Converge Pro 880 with a Device ID of 2 would have
the command line #12 MUTE 5 M 0.
In this command line, 1 = the Device Type for Converge 880, 2 = the Device ID for unit 2, MUTE = serial
command, 5 = the channel Value, M = the channel type Value for mic input channels, and 0 = the command
Value that turns mute off.