Parameters – Cabletron Systems 6A000/ZX-250 User Manual
Page 82

2-58 SmartCell 6A000/ZX-250 Reference Manual
Console Commands
Parameters
Input Parameter
Description
Value/Field Size
Default
[ClientNumber]
Number of the client.
0-127
ALL
[ServerType]
IP/ATM server type.
LOCAL,
EXTERNAL, NONE
NONE
[ServerAddress]
ATM address of the IP/ATM server. If
[ServerType]states NONE or LOCAL, then
accept the default. LOCAL means the client
also acts as an IP/ATM server for that VLAN
(virtual LAN). If [ServerType]states
EXTERNAL, enter the ATM address of the
external server.
13-20 byte hex-based/
Up to 59 characters
NONE
[IPAddress]
IP address of the client.
dot decimal/
7-15 characters
NONE
[NetMask]
IP netmask of the client. This parameter defaults
to the appropriate netmask, based on the class of
IP address. Must be specified only if IP subnets
are being used. Calculated from the first two
high bits of the IP address, so it is either
255.0.0.0, 255.255.0.0, or 255.255.255.0. With
less address left, you have fewer bits to use to
define subnets.
dot decimal/
7-15 characters
255.0.0.0,
255.255.0.0 or
255.255.255.0
[MTU]
Maximum transfer unit assigned for this client.
64 to 10160
9180