Table 2-1 filter flags (continued), 1 filter flags – Cabletron Systems 6A000/ZX-250 User Manual
Page 137

SmartCell 6A000/ZX-250 Reference Manual 2-113
Console Commands
[Quiet mode]
Suppresses the printing of messages to the console
but continues to forward messages to clients.
ON/OFF
ON
[Start record]
Starting record for message range. Log trace prints
messages within specified range. If both starting and
ending record numbers are set to infinity, log trace
captures all messages. All messages are always sent
to the client. However, console messages can be
filtered by setting the log trace flags on the switch.
5 characters
infinity
[Timestamp inactive]
Indicates how the time stamp will print on log
messages. In absolute
time is used (this resets to 0 at each reboot). In
relative
by setting the timestamp to 0. In delta mode,
the time difference between successive log messages
is printed.
ABS, REL, DEL
flag=0
[Filter Flags]
Limits printed messages to the designated message
type. Filter flag values are bitmapped, however,
enabling you to also print a combination of message
types by specifying alternate values. For example,
by entering 13, you can display messages that have
error, critical or emergency flags (13= 8 + 4 + 1). See
the following table:
See table below
n/a
Table 2-1 Filter Flags
MESSAGES PRINTED
VALUE
All messages printed
0
Emergency messages only
1
Alert messages only
2
Critical messages only
4
Error messages only
8
Warning messages only
16
Parameter
Description
Value/Field Size
Default