Descriptions – Cabletron Systems 6A000/ZX-250 User Manual

Page 66

background image

2-42 SmartCell 6A000/ZX-250 Reference Manual

Console Commands

Descriptions

Output Parameter

Description

[LES Address]

ATM address of the LANE server.

[Distribute VPI/VCI]

VPI/VCI values of the control direct VCC or multicast send VCC.

[Distribute Method]

Indicates whether the control distribute VCC is established for ALL clients or only
PROXY clients.

[LAN Type]

Type of ELAN.

[BUSATMAddress]

ATM address of the BUS (specify when the LES and BUS are not co-located).

Operator

Parameters/Permissions

Description

add elan

[ELANNumber]

[ELANName]

[ConnectMethod]

[ELANType]

[Multipoint]

[MTU]

[Distribute]

Administrator

Quickly configures the switch. This command adds the
ELAN entry in all three databases (BUSELAN,
LESELAN, and LECSELAN) and activates the ELAN.

delete elan

[ELANNumber]

Administrator

Quickly configures the switch. This removes a specific
ELAN. This command first checks that all servers
(LECS, LES, and BUS) exist before deleting any of
them.

show elan

[ELANNumber]

All

Displays an ELAN created by either the quick

add elan

or the multiple set of commands to add an ELAN. There
might not be LECS information (as seen in the first
example) if the ELAN was created by

add buselan

, and

add leselan

and

add lecselan

had not been completed.

The LECS information is displayed if you use

add elan

or if not, after you enter

add lecselan

(as seen in the

following B example below).