beautypg.com

Descriptions, Examples, Summarized report () – Cabletron Systems 6A000/ZX-250 User Manual

Page 204: Descriptions examples

background image

2-180 SmartCell 6A000/ZX-250 Reference Manual

Console Commands

Descriptions

Examples

The following examples show a summarized and detailed listing of an SVC.

Summarized Report ()

switch_prompt # show svc /s

PortNumber(ALL) :

CrossConnectId(ALL) :

Conn Conn Traffic Conn Low High Admin

Id SubId Type Type Port VPI/VCI Port VPI/VCI Status

============================================================================

4654 61 UBR PTP B4(CPU) 0/52 B4(CPU) 0/53 UP

4655 63 UBR PTP B4(CPU) 0/54 B4(CPU) 0/55 UP

4656 65 UBR PMP B4(CPU) 0/56 B4(CPU) 0/57 UP

switch_prompt #

[Number of Cells Received
in the Bkwd Direction]
(<

/d

>)

Number of cells received in the backward direction of this
cross-connect.

0, 1, 2, 3, 4.../
n/a

[Number of Cells Dropped
in the Bkwd Direction]
(<

/d

>)

Number of cells dropped in the backward direction of this
cross-connect.

0, 1, 2, 3, 4.../
n/a

[Number of EPD Packets
Droppedin the Bkwd
Direction] (<

/d

>)

Number of EPD packets dropped in the forward direction
of this cross-connect.

0, 1, 2, 3, 4.../
n/a

Operator

Parameters/Permissions

Description

show svc (/s |

/d)

[PortNumber] <portnumber>

[CrossConId <crossconnectid>

All

Displays SVCs configured for all ports or a specified port.
The cross-connect ID is a unique number generated for every
SVC. PMP SVCs have only one cross-connect ID, though
they might have several legs. All cell statistics are updated
every 40 seconds, which is the maximum time for holding
these counters without overflowing them.

Output Parameter

Description

Value/Field Size