beautypg.com

Lecstlvset, Operators, Parameters – Cabletron Systems 6A000/ZX-250 User Manual

Page 107: Lecstlvset 2-83

background image

SmartCell 6A000/ZX-250 Reference Manual 2-83

Console Commands

LECSTLVSet

Use LECSTLVSet (LAN emulation configuration server type, length, and value set) to manipulate TLV parameters on
the LECS. A TLV set is a collection of TLV parameters associated with an ELAN (emulated LAN).

Operators

add, delete, modify, show

Parameters

SERVER

SVC

X

Parameter

Description

Value/Field Size

Default

[TLVSetNumber]

Number that identifies the set of TLV
parameters on the LECS.

1-32767

1

[ControlTimeout]

Time-out period used for timing out most
request/response control-frame
interactions.

seconds/10-300

n/a

[MaxUnknownFrameCount]

Total counter frames a LANE client will
send to the LECS for a given unicast LAN
destination.

1-10

n/a

[MaxUnknownFrameTime]

Total time frames a LANE client will send
the LECS for a given unicast LAN
destination.

seconds/1-160

n/a

[VCCTimeout]

Time-out period for releasing a data direct
VCC on an LEC if it has not been used to
transmit or receive any data.

seconds/0-65535

n/a

[MaxRetryCount]

Maximum number of times a LEC should
try for a given LAN destination.

0-2

n/a

[ArpAgingTime]

Maximum time that a LEC maintains an
entry in its cache in the absence of updates.

seconds/10-300

n/a

[ForwardDelay]

Maximum time a LEC will maintain an
entry for a non-local MAC address in its
cache in the absence of updates.

seconds/4--30

n/a