Lecstlvset, Operators, Parameters – Cabletron Systems 6A000/ZX-250 User Manual
Page 107: Lecstlvset 2-83

SmartCell 6A000/ZX-250 Reference Manual 2-83
Console Commands
LECSTLVSet
Use LECSTLVSet (LAN emulation configuration server type, length, and value set) to manipulate TLV parameters on
the LECS. A TLV set is a collection of TLV parameters associated with an ELAN (emulated LAN).
Operators
add, delete, modify, show
Parameters
SERVER
SVC
X
Parameter
Description
Value/Field Size
Default
[TLVSetNumber]
Number that identifies the set of TLV
parameters on the LECS.
1-32767
1
[ControlTimeout]
Time-out period used for timing out most
request/response control-frame
interactions.
seconds/10-300
n/a
[MaxUnknownFrameCount]
Total counter frames a LANE client will
send to the LECS for a given unicast LAN
destination.
1-10
n/a
[MaxUnknownFrameTime]
Total time frames a LANE client will send
the LECS for a given unicast LAN
destination.
seconds/1-160
n/a
[VCCTimeout]
Time-out period for releasing a data direct
VCC on an LEC if it has not been used to
transmit or receive any data.
seconds/0-65535
n/a
[MaxRetryCount]
Maximum number of times a LEC should
try for a given LAN destination.
0-2
n/a
[ArpAgingTime]
Maximum time that a LEC maintains an
entry in its cache in the absence of updates.
seconds/10-300
n/a
[ForwardDelay]
Maximum time a LEC will maintain an
entry for a non-local MAC address in its
cache in the absence of updates.
seconds/4--30
n/a