2-6 SmartCell 6A000/ZX-250 Reference Manual

Console Commands

AlarmConfig

Use AlarmConfig (alarm configuration) to determine alarm message buffer file configuration.

Operators

add, modify, show

Parameters

SERVER

SVC

X

X

Input Parameter

Description

Value/Field Size

Default

[AlarmNumFiles]

Number of alarm files (within the flash file
system) to be used for saving alarm messages.

1, 2, 3, 4.../
1-32

32

[StartFileNum]

Offset to the starting file for alarm messages in
relation to number of alarm message files
specified by [

AlarmNumFiles].

0, 1, 2, 3, 4.../
n/a

0

[NumFilesUsed]

Number of files currently used within the alarm
message buffer (cannot exceed number of files to
store alarms).

0, 1, 2, 3, 4.../
n/a

0

[NumAlarmsPerFile]

Number of alarm messages that can be stored per
file within the alarm message buffer. Using a
smaller value results in less file system rewriting
but increases the space wasted per entry, as each
file has fixed overhead.

0, 1, 2, 3, 4.../
n/a

8

Output Parameter

Description

Default

[Alarm directory]

Name of the directory within the flash file system that contains the alarm
message buffer.

ALARM