SmartCell 6A000/ZX-250 Reference Manual 2-185

Console Commands

[Common DRAM]

Common DRAM memory size.

megabytes/Up to 4 characters

[SAR Control SRAM]

SAR control memory size.

kilobytes/Up to 5 characters

Power Mode

Type of power modules used by the
switch

Redundant, Non-Redundant

[Number of Switch
Boards]

Number of switch boards on the system.

1, 2

[Switch Board 1 ID]

Revision number of Board 1.

kilobytes/1-16

[Switch Board 2 ID]

Revision number of Board 2.

kilobytes/1-16

[Cell Memory Size]

Total cell buffer size.

bytes

[Number of Quad
Boards]

Number of quad boards on the system.

1, 2, 3, 4.../
n/a

[Number of Ports]

Number of installed ports, less CPU (for
example, if 8 ports are installed, 7 ports
are listed). One port (B4) is reserved for
CPU.

1, 2, 3, 4.../
n/a

[Quad Board Type]

Bandwidth of ports on each installed I/O
module. Bandwidth used to distinguish
between four port (155 Mbps) and single
port boards (622 Mbps).

155 Mbps, 622 Mbps

[IP Address]

IP address of the switch.

0.0.0.0 - 255.255.255.255

[MAC Address (Base)]

Base MAC (media access control)
address for the board. There are 128
addresses, starting at this base address.
The first is used for the Ethernet port.
The ATM stack uses all the addresses
(including the first).

00:20:d4:XX:XX:XX

[Switch Software Type]

Type of switch software package.

SVC, Server

[Software Version]

Version of the software.

X.X

[Build Number]

The build number for this version of
switch software.

XX

Output Parameter

Description

Value/Field Size