Sscopconfig, Operator, Parameters – Cabletron Systems 6A000/ZX-250 User Manual
Page 199: Sscopconfig 2-175

SmartCell 6A000/ZX-250 Reference Manual 2-175
Console Commands
SSCOPConfig
Use SSCOPConfig (service-specific connection-oriented protocol configuration) to view timers and other parameter
values.
Operator
show
Parameters
SERVER
SVC
X
X
Parameter
Description
Value/Field Size
Default
[Port#]
Port number on the switch.
ALL, A1...A4, B1...B3,
C1...C4, D1...D4
ALL
[MaxPD]
Number of SD (switching delay) PDUs (protocol data
unit) after which a poll PDU is generated.
5-20
10
[MaxCC]
Number of begin PDUs sent during line establishment. 4-10
4
[PollTm]
Time between generation of PDUs.
m/seconds/
100-200
200
[KpAliveTm]
Controls poll exchange rate in the absence of SD PDU
traffic.
m/seconds/
1000-2000/
1000
[NoRespTm]
Maximum time within which a poll has to be
acknowledged by a PDU.
m/seconds/
10000-15000
10000
[CCTm]
Rate at which begin and end PDUs are generated.
m/seconds/
1000-2000
1000
[TxWindowSz]
Setting of transmit direction window size.
32-256
256
[RxWindowSz]
Setting of receive window size.
32-256
256