beautypg.com

Sscopconfig, Operator, Parameters – Cabletron Systems 6A000/ZX-250 User Manual

Page 199: Sscopconfig 2-175

background image

SmartCell 6A000/ZX-250 Reference Manual 2-175

Console Commands

SSCOPConfig

Use SSCOPConfig (service-specific connection-oriented protocol configuration) to view timers and other parameter
values.

Operator

show

Parameters

SERVER

SVC

X

X

Parameter

Description

Value/Field Size

Default

[Port#]

Port number on the switch.

ALL, A1...A4, B1...B3,
C1...C4, D1...D4

ALL

[MaxPD]

Number of SD (switching delay) PDUs (protocol data
unit) after which a poll PDU is generated.

5-20

10

[MaxCC]

Number of begin PDUs sent during line establishment. 4-10

4

[PollTm]

Time between generation of PDUs.

m/seconds/
100-200

200

[KpAliveTm]

Controls poll exchange rate in the absence of SD PDU
traffic.

m/seconds/
1000-2000/

1000

[NoRespTm]

Maximum time within which a poll has to be
acknowledged by a PDU.

m/seconds/
10000-15000

10000

[CCTm]

Rate at which begin and end PDUs are generated.

m/seconds/
1000-2000

1000

[TxWindowSz]

Setting of transmit direction window size.

32-256

256

[RxWindowSz]

Setting of receive window size.

32-256

256