REPLACEMENT PARTS and ACCESSORIES
FlexPak 3000
49’1340 e
8-12
Radio Frequency Interference Filter
a) FlexPak 3000 converters with AC line input currents below 100 A:
If the RFI filter is connected, the HF emission limits for class A, group 1 (EN 55011) according to the
product standard EN 61800-3 are met and the drive is CE conform. This applies for the
1
st
environment (residential) as well as for the 2
nd
environment (industrial supply network).
b) FlexPak 3000 converters with AC line input currents above 100 A:
If the RFI filter is connected, the HF emission limits of class A, group 1 (EN 55011) in the 2
nd
environment (industrial supply network) are met, as required in the past for the Generic Standard
EN 50081-2. This is recommended if e.g. in industrial estates high power converters and offices with
sensitive consumers are connected to the same supply transformer.
The filter must be connected into the three AC line input phases L1 - L3 of the FlexPak 3000 in front of
the AC line reactor, as shown in figure H-1.
RFI Filter Selection
The RFI-Filters can be selected from Tab. 8-10 according to the permitted filter current and the
maximum operating voltage.
The permitted filter current is dependent on the application specific maximum continuous DC-current I
ad
of the drive, the DC-current form factor (FF) and the ambient temperature T.
The ambient temperature T is the max. temperature around the filter (typical 50
°
C inside cabinets for a
standard max. cooling air temperature of 40
°
C). Typical DC-current form factor FF = 1.05
For cabinet mounting with T = 50
°
C and FF = 1.05:
Filter current = maximum continuous DC-current I
ad
For other ambient temperatures (T) and form factors (FF) the continuous current of the filter can be
calculated as follows:
I
I
C
C T
FF I
C
C T
FILTER
Line rms
ad
=
Ч
°
° −
=
Ч
Ч
Ч
°
° −
(
)
45
85
2
3
45
85
Table 8-10:
RFI Filter Selection
RFI-Filter
Filter
380 - 440 V
460 - 500 V
690 V
Current
Part No.
see Page
Part No.
see Page
Part No.
see Page
Application
25A
839.72.05
8-13
on request
36A
839.72.06
8-13
on request
50A
839.72.07
8-13
on request
80A
839.72.09
8-14
on request
100A
839.71.53
8-15
839.71.53
8-15
according
to a)
150A
839.70.20
8-16
180A
839.74.22
8-17
on request
250A
839.73.25
8-20
on request
270A
839.70.66
8-18
839.70.66
8-18
280A
839.72.67
8-17
839.72.67
8-17
340A
839.71.68
8-19
839.71.68
8-19
500A
839.73.31
8-20
on request
600A
-
-
839.73.92
8-21
839.73.92
8-21
1000A
839.73.35
8-21
839.73.95
8-21
839.73.95
8-21
1600A
839.73.38
8-20
839.73.98
8-21
839.73.98
8-21
according
to b)