Rockwell Automation FlexPak 3000 Power Module Version 4.2 User Manual
Page 202

APPENDIX G
FlexPak 3000
49’1340 e
G-2
Table G.1 - User Quick Reference Table for Input Parameters (continued)
Par.
Parameter
Parameter Selection /
Pg Initial Factory
User Data
No.
Adjustment Range
B-
Setting
Date
Setting
105
ANLG MAN REF ZERO ADJ
-200 - +200
4
0
106
MANUAL REF SELECT
•
ANALOG
•
MOP
25
ANALOG
107
TRIM REF REGISTER
+ 100.0%
51
0%
108
TRIM REFERENCE SELECT
•
ANALOG MANUAL
•
ANALOG IN 1
•
NETW IN REG 1
•
NETW IN REG 2
•
NETW IN REG 3
•
ANALOG IN 2
•
REGISTER
51
REGISTER
109
TRIM RANGE
0 - +100.0%
51
0.0%
110
TRIM MODE SELECT
•
NO TRIM
•
INCREMENTAL
•
PROPORTIONAL (DRAW)
51
NO TRIM
111
AUTO MODE MIN BYPASS
•
OFF
•
ON
8
OFF
112
AUTO MODE RAMP BYPASS
•
OFF
•
ON
8
OFF
113
STOP SPEED THRESHOLD
0 - MAXIMUM SPEED (P.004)
in *RPM
49
0 (*RPM)
114
(3)
STOP MODE SELECT
•
RAMP
•
COAST/DB
•
CURRENT LIMIT
49
RAMP
115
MOP ACCEL TIME
ACCELERATION TIME (P.001) -
300.0 seconds
29
5.0 seconds
116
MOP RESET ENABLE
•
OFF
•
ON
30
OFF
117
PRESET SPEED 1
MINIMUM SPEED- MAX SPEED
43
250 *RPM
118
PRESET SPEED 2
MINIMUM SPEED- MAX SPEED
43
250 *RPM
119
PRESET SPEED 3
MINIMUM SPEED- MAX SPEED
43
250 *RPM
120
MOP DECEL TIME
DECEL.. TIME (P.002)- 300 sec
30
5.0 seconds
121
JOG OFF DELAY TIME
0.0 to 10.0 seconds
23
1.0 seconds
122
STOP DECEL SELECT
•
1 = DECELERATION TIME
•
2 = RAMP STOP DECEL TIME
48
1
Feedback Selection
200
FEEDBACK SELECT
•
ARMATURE VOLT
•
DC TACH
•
PULSE TACH
•
AC TACH
14 ARM VOLT for
S-6
DC TACH for
S-6R
201
ANALOG TACH GAIN ADJ
0.750 - 1.250
1
1.000
202
ANALOG TACH ZERO ADJ
-200 - +200
2
0
203
ANLG TACH VOLTS/1000
18.0 - 200.0 V/1000 RPM
6
60V/1000 RPM
204
ARM VOLTAGE GAIN ADJ
0.750 - 1.250
7
1.000
205
ARM VOLTAGE ZERO ADJ
-200 - +200 V
8
0 V
206
IR COMPENSATION
0 - 50 %FLA
22
0% FLA
(*) Or user defined unit.
(3) If drive is configured as a current regulator,