Rockwell Automation FlexPak 3000 Power Module Version 4.2 User Manual
Page 166
APPENDIX C
FlexPak 3000
49’1340 e
C-10
PULSE TACH FEEDBACK (P.292)
The digital value from the pulse tachometer after all hardware and software scaling.
For use with pulse tachometer feedback only.
OIM Menu Path(s):
Speed/Voltage Loop (SPD) - Speed/Voltage Loop (SPD) Test Points
PULSE TACHOMETER KIT (P.798)
Indicates the presence of a pulse tach kit.
OIM Menu Path(s):
Drive Information
REGULATOR SW VERSION (P.794)
Indicates the regulator software version.
OIM Menu Path(s):
Drive Information
SPD LOOP ERROR (P.297)
The speed loop error signal, which represents the difference between the SPD LOOP REFERENCE and
the SPD LOOP FEEDBACK signals.
OIM Menu Path(s):
SPD - Speed/Voltage Loop (SPD) Test Points
SPD LOOP FEEDBACK (P.296)
An output that represents the selected speed/voltage loop drive feedback value after all scaling.
OIM Menu Path(s):
SPD - Speed/Voltage Loop (SPD) Test Points
SPD LOOP LAG OUTPUT (P.298)
An output representing the value immediately after the Speed Loop Lag function.
OIM Menu Path(s):
SPD - Speed/Voltage Loop (SPD) Test Points
SPD LOOP OUTPUT (P.299)
Speed Loop PI function output value to the CML.
OIM Menu Path(s):
SPD - Speed/Voltage Loop (SPD) Test Points
Current Minor Loop (CML) - CML Test Points
SPD LOOP REFERENCE (P.295)
An output that represents the reference value to be used by the speed loop regulator in the drive.
OIM Menu Path(s):
SPD - Speed/Voltage Loop (SPD) Test Points,
Drive Reference - Drive Reference Test Points
SPD SOURCE SELECT OUT (P.193)
The user selected speed reference source value. It is an input to the speed reference ramp section.
OIM Menu Path(s):
Drive Reference - Drive Reference Test Points