Rockwell Automation GV3000/SE AC Drive AutoMax Network Communication Board, M/N 2AX3000 User Manual
Page 89

B-6
AutoMax Network Communication Option Board for the GV3000/SE AC Drive
P.062, Option Port: Comm Loss Response
1
29
1
62
P.063, Option Port: Network Ref Source
1
30
0 to 7
1
63
0 to 7
P.064, Option Port: Netw Trim Ref Source
1
30
8 to 15
1
63
8 to 15
P.065, Option Port: Type and Version
2
31
n/a
P.066, Network Output Register 1 Source
2
3
0 to 7
2
45
0 to 7
P.067, Network Output Register 2 Source
2
3
8 to 15
2
45
8 to 15
P.068, Network Output Register 3 Source
2
4
0 to 7
2
46
0 to 7
P.069, Network Output Register 4 Source
2
4
8 to 15
2
46
8 to 15
P.090, Diagnostics Source
n/a
n/a
P.091, Diagnostics Display
n/a
n/a
P.095, Power Module Output Amps
3, V/Hz
27
n/a
P.098, Software Version Number
1
31
n/a
P.099, Power Module Type
3
31
n/a
Parameter processing error flag
1
14
8
n/a
Power Module not identified (PUn)
1
13
10
n/a
Power Module Output Amps (P.095)
3, V/Hz
27
n/a
Power Module Type (P.099)
3
31
n/a
Programming Disable (P.051)
n/a
n/a
PUc (missing Power Module ID connector)
1
13
9
n/a
PUn (Power Module not identified)
1
13
10
n/a
PUo (drive power electronic overload)
1
13
6
n/a
Restore Defaults (P.050)
n/a
n/a
RMI (r.) parameters
n/a
n/a
Rotor Time Constant (U.021)
3, Vector
17
3, Vector
46
Run/jog status
1
0
3
n/a
Run/jog select
n/a
1
32
3
S-Curve Enable (P.019)
2
11
2
39
Selected speed reference value
1
1
n/a
Self-tuning status (SF)
1
12
12
n/a
Sequencing control word
n/a
1
32
Slip Compensation (H.004)
3, V/Hz
4
3, V/Hz
36
Software Version Number (P.098)
1
31
n/a
Speed Display Scaling (P.028)
2
18
1
52
Speed feedback
1
3
n/a
Speed reference sum
1
2
n/a
Speed regulation select
n/a
1
32
7
Speed Regulator Integral Gain (U.013)
1
25
1
48
Speed Regulator Prop Gain (U.012)
1
24
1
47
Spurious host PC comm interrupt (UAr)
1
12
11
n/a
SrL (comm loss between
Regulator/PC/OIM)
1
12
10
n/a
Start
n/a
1
32
0
Status word 1
1
0
n/a
Status word 2
1
26
n/a
Stop
n/a
1
32
1
Stop sequence in progress
1
0
5
n/a
Stop Type (P.025)
2
15
0 to 7
1
50
STOP
/
RESET
Key Disable (P.055)
2
24
4
2
38
4
SVC Flux Current Regulator Gain (U.032)
3, Vector
22
3, Vector
55
SVC Slip Adjust (U.030)
3, Vector
20
3, Vector
53
SVC Sync Direction (U.031)
3, Vector
21
0 to 7
3, Vector
54
0 to 7
Description or GV3000/SE Parameter
Read Only
Read/Write
Drop
Register
Bit
Drop
Register
Bit