Rockwell Automation GV3000/SE AC Drive AutoMax Network Communication Board, M/N 2AX3000 User Manual
Page 75
![background image](/manuals/581449/75/background.png)
5-12
AutoMax Network Communication Option Board for the GV3000/SE AC Drive
T
a
b
le
5.6 –
Register A
ssignm
ent
f
o
r Dro
p_3 A
rea (
V
ector)
Read Only
Registers
Regis
te
r
Bit
D
es
cr
iption
or
G
V
30
00/SE
P
a
ra
meter
S
ettings
U
p
da
te
*
0
0
t
o
7
T
or
q
u
e
R
e
fe
re
nc
e S
o
ur
c
e
(
U
.0
00
).
350
ms
8 t
o
1
5
O
u
te
r C
o
n
trol
Loo
p F
e
e
dba
c
k
Se
lec
t (U
.040
)
350
ms
1
E
nc
od
er
PPR
(U
.001
)
0
=
51
2;
1
=
1
024
; 2
=
20
48;
3
=
409
6;
4
=
S
E
350
ms
2
M
oto
r P
o
le
s (U
.002
)
0
=
2
; 1
=
4;
2
=
6;
3
=
8 p
o
le
s
350
ms
3
M
oto
r N
a
m
epl
ate
Bas
e
F
req
uen
cy
(U
.0
03)
1 =
0.1
H
z
350
ms
4
M
oto
r N
a
m
epl
ate
Amp
s
(U
.004
)
1
=
0.1
am
ps
350
ms
5
M
oto
r N
a
m
epl
ate
R
P
M
(U
.005
)
1 =
1
RPM
350
ms
6
M
agn
eti
z
ing C
u
rren
t (U
.00
6
)
350
ms
7
M
o
to
r N
a
m
epl
ate
V
o
lt
s
(U
.007
)
1
=
1 v
o
lt
s
350
ms
8
T
o
rque
Sel
f-T
u
ne R
e
su
lt (U
.009
)
S
ee
dr
iv
e
sof
tw
a
re
ins
tr
u
cti
on
man
ual
350
ms
9
R
es
er
v
e
d
10
T
o
rque
R
e
g
u
la
tor Pr
opo
rt
io
nal
G
a
in
(U
.01
4
)
1
=
0.0
1
350
ms
11
T
o
rque
R
e
g
u
la
tor I
n
te
g
ra
l G
a
in
(U
.0
15
)
1
=
0.1
350
ms
12
Fi
eld
W
e
ak
e
n
in
g Sta
rt R
P
M
(U
.01
6
)
1
=
1 R
P
M
350
ms
13
M
o
to
r T
o
p
Spe
ed
(U
.017
)
1
=
1 R
P
M
350
ms
1
4
A
C
Li
ne
V
o
lt
s (
U
.0
18
)
1
= 1
v
o
lt
s
3
5
0
m
s
15
Fl
ux
C
u
rre
nt R
e
gul
ator
Prop
o
rt
iona
l G
a
in
(U
.0
19)
1 =
0.0
1
350
ms
16
Fl
ux
C
u
rre
nt R
e
gul
ator
Inte
g
ral
Ga
in
(U
.020
)
1
=
0.1
350
ms
17
R
o
to
r Ti
me
C
o
n
s
ta
nt (U
.0
21
)
1
=
0.0
0
1
se
co
nds
350
ms
18
M
o
to
r N
a
m
epl
ate
H
o
rs
epo
w
e
r (U
.0
22)
1 =
0.1
H
P
350
ms
19
Ze
ro Sp
eed
H
o
ld
Ti
me
(U
.02
5
)
1
=
0.1
s
e
co
nd
s
350
ms
20
SVC
Sl
ip Adju
st (U
.030
)
1
=
0.0
1
350
ms
21
0
to 7
SVC
Sy
nc
D
ire
cti
on
(U
.03
1
)
S
ee
dr
iv
e
sof
tw
a
re
ins
tr
u
cti
on
man
ual
350
ms
8
to
15
Ou
te
r C
o
nt
ro
l L
o
o
p
Le
a
d
/L
ag
S
e
le
ct
(
U
.0
4
1
)
0
= b
y
pa
ss
; 1 =
le
ad
/l
ag
;
2
=
l
a
g/
le
ad
3
5
0
m
s
22
SVC
Fl
ux
C
u
rre
nt R
e
gul
ato
r G
a
in
(U
.03
2
)
1
=
1 r
a
d/s
350
ms
23
O
u
te
r C
o
n
trol
Loo
p L
ead
/La
g
L
o
w
F
requ
en
cy
(U
.04
2
)
1
=
0.0
1
r
a
d/s
350
ms
24
O
u
te
r C
o
n
trol
Loo
p L
ead
/La
g
R
a
ti
o
(U
.043
)
1
=
1
350
ms
25
O
u
te
r C
o
n
trol
Loo
p R
e
fe
re
nc
e G
a
in
(U
.0
44)
1 =
0.0
0
1
350
ms
*U
pda
te
Times: 3
50 ms
= 350
ms or
less
.
m
a
g
net
iz
ing
am
ps
ra
ted
am
ps
---
---
----
---
---
---
----
---
---
----
---
---
----
---
--
10
00
Ч