beautypg.com

Rockwell Automation GV3000/SE AC Drive AutoMax Network Communication Board, M/N 2AX3000 User Manual

Page 56

background image

Drive Configuration

3-9

P.066 to P.069 Network Output Register 1 Source through
Network Output Register 4 Source

These parameters
select the signal
written to the option
port network output
registers 1 through 4.

See figure 3.1.

Parameter Range:

0 = (P.066) Motor Kw display value

(P.067) Motor torque display value
(P.068) Output power factor
(P.069) Encoder counter (x4)

1 = Speed reference rate limit output (vector only)

2 = Speed reference at the ref/fdbk summing

junction (includes

OCL

output and current

compounding) (vector only)

3 = Speed loop feedback (vector only)

4 = Speed loop error (vector only)

5 = Speed PI output (vector only)

6 = Outer control loop feedback (vector only)

7 = Outer control loop error (vector only)

8 = Outer control loop output (vector only)

9 = Terminal strip analog input normalized to speed

(see drive software instruction manual)

10 = Terminal strip analog input scaled (see drive

software instruction manual)

11 = Torque reference (vector only)

12 = Torque feedback (vector only)

Default Setting:

0

Parameter Type:

Tunable

Refer also to parameters:

N/A