Rockwell Automation GV3000/SE AC Drive AutoMax Network Communication Board, M/N 2AX3000 User Manual
Page 85
B-2
AutoMax Network Communication Option Board for the GV3000/SE AC Drive
Drive panel amps
3
28
n/a
Drive panel volts
3
29
n/a
Drive power electronic overload (PUo)
1
13
6
n/a
Drive ready
1
0
0
n/a
Drive running
1
0
1
n/a
Earth current failure (ground fault) (EC)
1
13
7
n/a
EEr
1
13
5
n/a
EL
1
13
12
n/a
Elapsed Time Meter (P.029)
1
27
1
53
0
Electronic thermal overload (OL)
1
12
6
n/a
Encoder loss (EL)
1
13
12
n/a
Encoder Loss Enable (P.039)
2
24
0
2
38
0
Encoder PPR (U.001)
3, Vector
1
3, Vector
32
Error log clear
n/a
1
32
8
Error log entry (most recent error)
1
15
8 to 15
n/a
Error log entry (second most recent)
1
15
0 to 7
n/a
Fatal system error
1
13
15
n/a
Fault active
1
0
2
n/a
Fault Auto Reset Attempts (P.043)
2
22
2
43
Fault Auto Reset Time (P.044)
2
23
2
44
Fault reset
n/a
1
32
2
Field Weakening Start RPM (U.016)
3, Vector
12
3, Vector
41
FL (function loss)
1
12
8
n/a
Flux Current Regulator Integral Gain (U.020)
3, Vector
16
3, Vector
45
Flux Current Regulator Prop. Gain (U.019)
3, Vector
15
3, Vector
44
Forward/Reverse Configuration (P.027)
2
17
2
37
Forward/reverse reference invert
1
0
4
n/a
Forward/reverse select
n/a
1
32
4
Function loss (FL)
1
12
8
n/a
Function Loss Response (P.026)
2
16
1
51
H.000, Motor Nameplate Volts
3, V/Hz
0
3, V/Hz
32
H.001, Motor Nameplate Base Freq.
3, V/Hz
1
3, V/Hz
33
H.002, Motor Nameplate Amps
3, V/Hz
2
3, V/Hz
34
H.003, Torque Boost Voltage
3, V/Hz
3
3, V/Hz
35
H.004, Slip Compensation
3, V/Hz
4
3, V/Hz
36
H.005, DC Braking Enable
3, V/Hz
5
3, V/Hz
37
0
H.006, DC Braking Start Frequency
3, V/Hz
6
3, V/Hz
38
H.007, DC Braking Current
3, V/Hz
7
3, V/Hz
39
H.008, DC Braking Time
3, V/Hz
8
3, V/Hz
40
H.009, Avoidance Frequency Enable
3, V/Hz
9
0
3, V/Hz
41
0
H.010, Avoidance Frequency Midpoint 1
3, V/Hz
10
3, V/Hz
42
H.011, Avoidance Frequency Band 1
3, V/Hz
11
3, V/Hz
43
H.012, Avoidance Frequency Midpoint 2
3, V/Hz
12
3, V/Hz
44
H.013, Avoidance Frequency Band 2
3, V/Hz
13
3, V/Hz
45
H.014, Avoidance Frequency Midpoint 3
3, V/Hz
14
3, V/Hz
46
H.015, Avoidance Frequency Band 3
3, V/Hz
15
3, V/Hz
47
H.016, Sync Direction
3, V/Hz
16
3, V/Hz
48
H.017, Input Power/Snubber Config.
3, V/Hz
17
3, V/Hz
49
H.018, Volts/Hertz Curve Type
3, V/Hz
18
3, V/Hz
50
H.019, Identification Result
3, V/Hz
19
n/a
H.020, Identification Request
n/a
n/a
Description or GV3000/SE Parameter
Read Only
Read/Write
Drop
Register
Bit
Drop
Register
Bit