Installation

2-15

Step 5.

Reinstall the Keypad Bracket in the Drive

Step 5.1 Place the keypad support bracket back into position. Use a magnetic

screwdriver to fasten it to the heatsink with the screws removed earlier.

Step 5.2 Realign the 26-conductor ribbon cable connector with the connector inside

the slot in the keypad support bracket. Carefully press the ribbon cable
connector in until the retaining clips lock into place.

Step 5.3 Route the Network Drop Cable through the left-most opening at the bottom

of the drive.

Step 5.4 Connect the brown wire to terminal 1 of the 2-connector terminal strip.

Connect the white wire to terminal 2.

Step 5.5 Reconnect any wiring that was removed from the Regulator board.

Step 5.6 NEMA 4X/12 drives only: Before installing the cover, check that the gaskets

on the cover are flat and within the gasket channels.

Step 5.7 Reinstall the cover. Align all cover screws into the heat sink before

tightening any of them.

To maintain the integrity of NEMA 4X/12 drives, sequentially tighten the
cover screws to ensure even compression of the gaskets. Do not exceed
2.2 Nm (20 in-lb) of torque on these screws.

This completes the hardware installation of the AutoMax Network option board. Do not
remove the lockout and tag until you have completed section 2.10, which provides