Installation
2-31
Step 4.3 Fasten the board to the drive with four
″
nuts. Metal nuts must be used
for proper grounding of the AutoMax Network option board.
Step 4.4 Connect the brown wire to terminal 1 of the 2-connector terminal strip.
Connect the white wire to terminal 2.
Step 4.5 Align the key on the connector of the AutoMax Network option board ribbon
cable with the key on the Regulator board connector. Press the ribbon
cable connector in until it locks into position.
Step 4.6 Route the Network Drop Cable through the signal wiring tray on the right
side of the drive.
Step 5.
Reinstall the Keypad Bracket in the Drive
Step 5.1 Align the key on the connector from the Regulator board with the key of the
connector on the Power Module Interface board. Press the ribbon cable
connector in until it locks into position.
Step 5.2 Reconnect the keypad bracket to the hinged mounting panel using the four
screws removed earlier.
Step 5.3 Reconnect any wiring that was removed from the Regulator board.
Step 5.4 Close and secure the outer cabinet door of the drive.
This completes the hardware installation of the AutoMax Network option board. Do not
remove the lockout and tag until you have completed section 2.10, which provides
instruction on connecting to the AutoMax network.
7