Terminal Block Group (continued)
t077 [Relay Out1 Level]
Related Parameter(s):
t082 [Relay Out2 Level]
PowerFlex 525 only.
32 bit parameter.
Determines the on/off point for the output relay when
[Relay Outx Sel] is set to the values shown below.
Values
Default:
0
Min/Max:
0/9999
Display:
1
PF 525
32
Min/Max Value Range Based On [Relay Outx Sel] Setting
6:
0...500 Hz
10: 0...100%
16: 0.1...9999 s
20: 0/1
7:
0...180%
11: 0/1
17: 1...9999 counts 26: 0...150%
8:
0...815V
13: 0...800
18: 0...180
°
–
t079 [Relay 1 On Time]
t084 [Relay 2 On Time]
PowerFlex 525 only.
Sets the delay time before Relay energizes after required condition is met.
Values
Default:
0.0 s
Min/Max:
0.0/600.0 s
Display:
0.1 s
PF 525
t080 [Relay 1 Off Time]
t085 [Relay 2 Off Time]
PowerFlex 525 only.
Sets the delay time before Relay de-energizes after required condition ceases.
Values
Default:
0.0 s
Min/Max:
0.0/600.0 s
Display:
0.1 s
PF 525
t086 [EM Brk Off Delay]
Sets the time the drive remains at minimum frequency before ramping up to the commanded frequency (and engaging the brake coil relay) if Electromechanical (EM) Brake Control
Mode is enabled with
[Stop Mode].
Values
Default:
2.00 s
Min/Max:
0.00/10.00 s
Display:
0.01 s
Frequency
Time
[Minimum Freq]
[EM Brk Off Delay]
[EM Brk On Delay]
Stop
commanded
Start
commanded
EM Brk
de-energized (On)
Drive stops
EM Brk
energized (Off)
Ramp accel
Ramp decel