Advanced display group (continued) – Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual
Page 106

106
Rockwell Automation Publication 520-UM001G-EN-E - September 2014
Chapter 3
Programming and Parameters
Advanced Display Group (continued)
d389 [Units Traveled L]
Stop drive before changing this parameter.
PowerFlex 525 only.
Displays the number of user-defined units traveled from the home position. See
[Position Status] for direction of travel.
Values
Default:
Read Only
Min/Max:
0.00/0.99
Display:
0.01
PF 525
d390 [Fiber Status]
Present status of the Fibers features.
Values
Default:
Read Only
Min/Max:
0000/1111
Display:
0000
1 = Condition True, 0 = Condition False
Sync Hold
Digit 1
Sync Ramp
Digit 2
Traverse On
Digit 3
Traverse Dec
Digit 4
Not Used
d391 [Stp Logic Status]
Related Parameter(s):
32 bit parameter.
PowerFlex 525 only.
Displays the current step of the Step Logic profile as defined by parameters
[Step Logic x] when
[Speed Reference1] is set to 13 “Step Logic” or 16 “Positioning”.
Values
Default:
Read Only
Min/Max:
0/8
Display:
1
32
PF 525
d392 [RdyBit Mode Act]
PowerFlex 525 only.
(With FRN 3.xxx and later.)
Displays the value of
[RdyBit Mode Cfg].
Values
Default:
Read Only
Min/Max:
0/1
Display:
1
PF 525