Rockwell Automation 25B PowerFlex 520-Series Adjustable Frequency AC Drive User Manual User Manual
Page 41

Rockwell Automation Publication 520-UM001G-EN-E - September 2014
41
Installation/Wiring
Chapter 1
06
DigIn TermBlk 06 Preset Freq
Program with t066 [DigIn TermBlk 06].
Current consumption is 6 mA.
07
DigIn TermBlk 07/
Pulse In
Start Source 2
+ Speed
Reference2
Program with t067 [DigIn TermBlk 07]. Also functions as a Pulse
Train input for reference or speed feedback. The maximum
frequency is 100 kHz. Current consumption is 6 mA.
08
DigIn TermBlk 08 Jog Forward
Program with t068 [DigIn TermBlk 08].
Current consumption is 6 mA.
C1
C1
–
This terminal is tied to the RJ-45 port shield. Tie this terminal to
a clean ground in order to improve noise immunity when using
external communication peripherals.
–
C2
C2
–
This is the signal common for the communication signals.
–
S1
Safety 1
–
Safety input 1. Current consumption is 6 mA.
–
S2
Safety 2
–
Safety input 2. Current consumption is 6 mA.
–
S+ Safety +24V
–
+24V supply for safety circuit. Internally tied to the +24V DC
source (Pin 11).
–
11
+24V DC
–
Referenced to Digital Common.
Drive supplied power for digital inputs.
Maximum output current is 100 mA.
–
12
+10V DC
–
Referenced to Analog Common.
Drive supplied power for 0...10V external potentiometer.
Maximum output current is 15 mA.
13
±10V In
Not Active
For external 0-10V (unipolar) or ±10V (bipolar) input supply or
potentiometer wiper.
Input impedance:
Voltage source = 100 k
Ω
Allowable potentiometer resistance range = 1...10 k
Ω
,
,
,
14
Analog Common
–
Return for the analog I/O. Electrically isolated (along with the
analog I/O) from the rest of the drive.
–
15
4-20mA In
Not Active
For external 4-20 mA input supply.
Input impedance = 250
Ω
,
,
,
16
Analog Output
OutFreq 0-10
The default analog output is 0-10V. To convert a current value,
change the Analog Output jumper to 0-20 mA. Program with
t088 [Analog Out Sel]. Maximum analog value can be scaled
with t089 [Analog Out High].
Maximum Load: 4-20 mA = 525
Ω (10.5V)
0-10V = 1 k
Ω (10 mA)
17
Opto Output 1
Motor Running Program with t069 [Opto Out1 Sel].
Each Opto-Output is rated 30V DC 50 mA (Non-inductive).
,
18
Opto Output 2
At Frequency
Program with t072 [Opto Out1 Sel].
Each Opto-Output is rated 30V DC 50 mA (Non-inductive).
,
19
Opto Common
–
The emitters of the Optocoupler Outputs (1 and 2) are tied
together at Optocoupler Common. Electrically isolated from the
rest of the drive.
–
(1) See Footnote (1) on
Control I/O Terminal Designations
No. Signal
Default
Description