10 troubleshooting, Troubleshooting – JLG G12-55A AccuPlace Service Manual User Manual
Page 41

3.19
G10-55A & G12-55A AccuPlace
Boom
3.10
TROUBLESHOOTING
This section provides an easy reference guide covering
the most common problems that occur during operation
of the boom.
Problem
Cause
Remedy
1. Boom will not extend or
retract.
1. Broken hydraulic hose(s) or
tube(s) and/or connections
leaking.
1. Locate break, replace hose(s)
or tube(s), tighten connections.
2. Extend/retract hydraulic system
not operating properly.
2. Refer to Section 8.4, “Hydraulic
3. Faulty extend/retract cylinder.
3. Repair cylinder. Refer to Section
8.10.1, “General Cylinder
Removal Instructions.”
4. Electronic control function not
operating properly.
4. Check for DTC. Refer to Section
9.15.8, “Diagnostic Trouble
Code (DTC) Table.”
2. Boom shifts to right or left
when extending.
1. Boom side wear pads
improperly shimmed or worn.
1. Shim wear pads to correct gap.
Replace wear pads as needed.
Refer to Section 3.7.2, “Boom
Wear Pad Replacement.”
3. Excessive boom pivot pin
noise and/or wear.
1. Insufficient lubrication.
1. Lubricate at regular intervals.
Refer to Section 2.6,
“Lubrication Schedules.”
Replace worn pins as needed.
2. Worn bearing(s).
2. Replace bearing(s) and
lubricate at regular intervals.
Refer to Section 2.6,
“Lubrication Schedules.”