9.69
G10-55A & G12-55A AccuPlace
Electrical System
LEFT 
STABILIZER UP 
VALVE – OPEN 
CIRCUIT
2
33225 Voltage on UGM pin J2-9
indicates solenoid 
disconnected.
N
Check for continuity through this circuit.
Inspect wiring for physical damage.
Note: An open circuit voltage of nearly 
8.0V exists on this UGM pin for circuit 
diagnostic purposes.
LEFT 
STABILIZER UP 
VALVE – SHORT 
TO BATTERY
33226 Voltage on UGM pin J2-9
indicates STB fault.
N
Check for continuity through this circuit.
Inspect wiring for physical damage.
Note: The wire on the low side of the coil 
provides current feedback to J3-14 and 
can open circuit the electrical path to 
ground to prevent current flow through the 
coil (to prevent function movement).
LEFT 
STABILIZER UP 
VALVE – SHORT 
TO GROUND
33227 Loss of current feedback on
UGM pin J3-14 while driving 
coil via UGM pin J2-9; 
assessed at startup.
N
Check for continuity through this circuit.
Inspect wiring for physical damage.
LEFT 
STABILIZER – 
CURRENT 
FEEDBACK 
READING TOO 
LOW
3334
Current feedback on UGM 
pin J3-14 > 250ma; but 
difference from commanded 
current while driving coil via 
UGM pin J2-9 > 125ma for 1 
second.
N
Check for continuity through this circuit.
Inspect wiring for physical damage.
Check the current on the Feedback wire 
returning to UGM pin J3-14. This current 
should read within 20ma of the value 
commanded as read on the Analyzer 
under Diagnostics/Ground for either Left 
Stabilizer Up or Down functions; 
otherwise, there is a degraded 
connection. If the value does not track, 
temporarily swap connections to assess 
whether and how the fault follows the 
wiring.
RIGHT 
STABILIZER 
DOWN VALVE – 
OPEN CIRCUIT
2
33228 Voltage on UGM pin J2-19
indicates solenoid 
disconnected.
N
Check for continuity through this circuit.
Inspect wiring for physical damage.
RIGHT 
STABILIZER 
DOWN VALVE – 
SHORT TO 
BATTERY
33229 Voltage on UGM pin J2-19
indicates STB fault.
N
Check for continuity through this circuit.
Inspect wiring for physical damage.
Note: The wire on the low side of the coil 
provides current feedback to J3-14 and 
can open circuit the electrical path to 
ground to prevent current flow through the 
coil (to prevent function movement).
Help Message
1
DTC
Fault Condition
(for configurable items,
fault applies only if
configured)
Fault
Requires
AccuPlace
Reset?
Action(s)