JLG G12-55A AccuPlace Service Manual User Manual
Page 163

9.45
G10-55A & G12-55A AccuPlace
Electrical System
Fork Up End of Stroke Threshold
“FORK UP SOFT ZN”
23.0 DEG
0.0 -50.0 DEG
Fork Down End of Stroke Threshold
“FORK DN SOFT ZN”
-115.0 DEG
-125.0 - (-90.0) DEG
Fork Tilt Flow Priority
“FORK FLOW PRIOR”
False
True/False
Auxiliary Hydraulics Flow Priority
“AUX FLOW PRIOR”
False
True/False
Lift Down Derating When Telescoped Out
“LIFT DN DERATE”
0.5
0.2-0.9
Lift Down Derating When Telescoped Out
Begin Point
“LIFT DN DERATE START”
4.26 FT
(1300mm)
1.64-9.18 FT
(500-2798mm)
Lift Down Engine Speed Dependency
“LIFT DOWN SPEED”
RPM BASED
RPM BASED/NOT
RPM BASED
AccuPlace Vertical Height Limit
“ACCUPLACE MAX HEIGHT”
52.7 FT
44.9-59.9 FT
Allow Difference Between Boom Angle
Readings
“ALLOWED BM ANGLE DIFF”
±8 DEG
±4 to ±10 DEG
Function
Personality
Default Setting
Adjustment Range