JLG G12-55A AccuPlace Service Manual User Manual
Page 217

9.99
G10-55A & G12-55A AccuPlace
Electrical System
CANBUS 
FAILURE – FORK 
VALVE
6628
ISP communicates 
SPN/FMI: 2163/11
Y
Cycle power to see if fault clears.
If multiple CAN Bus faults are occurring, 
the integrity of connections and continuity 
of the entire CAN Bus must be checked. 
Otherwise, with power off, unplug the Fork 
Valve and with a multimeter verify 
approximately 60ohms between CANH 
and CANL in the machine harness. Turn 
power on and verify +12V between power 
and ground pins. Also, verify that the 
ground pin has less than 1.0ohms 
resistance to a good chassis (B-) 
connection. Turn power off, reconnect 
Fork Valve, and power on. If fault still 
exists, unplug connector to Fork Valve 
and verify the connectivity in the 12-pin 
Deutsch connector. Remove the wedge 
and pull each termination back past the 
rubber seal. Lightly tug on each wire and 
inspect the crimp.
CANBUS 
FAILURE – 
TELEMATICS 
LOADING TOO 
HIGH
6629
An excessive number of 
messages are being 
broadcast from the 
Telematics Control Unit.
N
This fault may cause an inoperable 
joystick. Disconnect the Telematics 
Control Unit from CAN2. If fault still exists, 
check power and CAN connections within 
CAN2 cab harness.
CANBUS 
FAILURE – ISP
6630
UGM has not received a 
CAN Bus message from the 
ISP within 60ms.
Y
Cycle power to see if fault clears.
If multiple CAN Bus faults are occurring, 
the integrity of connections and continuity 
of the entire CAN Bus must be checked. 
Otherwise, with power off, unplug the ISP 
and with a multimeter verify approximately 
60ohms between CANH and CANL in the 
machine harness. Turn power on and 
verify +12V between power and ground 
pins. Also, verify that the ground pin has 
less than 1.0ohms resistance to a good 
chassis (B-) connection. Turn power off, 
reconnect ISP, and power on. If fault still 
exists, unplug connector to ISP and verify 
the connectivity in the 12-pin Deutsch 
connector. Remove the wedge and pull 
each termination back past the rubber 
seal. Lightly tug on each wire and inspect 
the crimp.
Help Message
1
DTC
Fault Condition
(for configurable items,
fault applies only if
configured)
Fault
Requires
AccuPlace
Reset?
Action(s)