JLG G12-55A AccuPlace Service Manual User Manual
Page 226

Electrical System
9.108
G10-55A & G12-55A AccuPlace
FUNCTIONS 
LOCKED OUT – 
FORK VALVE 
SOFTWARE 
VERSION 
IMPROPER
2
9983
Fork valve controller has 
incompatible software 
version.
N
Software update required.
FUNCTIONS 
LOCKED OUT – 
ISP SOFTWARE 
VERSION 
IMPROPER
2
9984
ISP controller has 
incompatible software 
version.
N
Software update required.
FUNCTIONS 
LOCKED OUT –
CAB JOYSTICK 
SOFTWARE 
VERSION 
IMPROPER
2
9985
Joystick software version 
improper.
N
Verify proper UGM software; then replace 
joystick.
CAB JOYSTICK 
INTERNAL 
FAILURE
9976
Joystick has observed an 
internal hardware fault or 
inconsistency.
N
Cycle power to see if fault clears.
If faults persists, replace joystick.
EEPROM 
FAILURE – 
CHECK ALL 
SETTINGS
998
Controls have detected 
corruption in the UGM 
EEPROM settings.
Y
Cycle power to see if fault clears.
If fault persists, record all Machine Setup 
and Personality parameters. Next, toggle 
model from existing model to another 
machine model and back. This will 
effectively set EEPROM values to default. 
Adjust the Machine Setup and Personality 
parameters to previous values.
GROUND 
MODULE VLOW 
FET FAILURE
9986
VLow FET determined to 
have failed on startup. UGM 
is unable to read high-
sensing digital inputs.
N
Cycle power to see if fault clears.
This fault indicates internal hardware 
failure and may require UGM 
replacement.
INCOVA 
MACHINE SETUP 
DATA NOT 
WRITTEN
9987
The UGM to INCOVA Setup 
data was not successfully 
written to ISP, Lift, Tele, and 
Fork Valves at startup.
N
This fault may occur when the CAN Bus 
communications are of poor quality.
Cycle power to see if fault clears.
Check the amount of CAN1 traffic and 
errors via the Analyzer under 
DIAGNOSTICS/CAN STATISTICS. 
Expected ranges of values are CAN1 Rx/
s ~ 600-700; CAN1 Tx/s ~ 100-150; CAN1 
ERR F/S = 0. Troubleshoot CAN Bus if 
errors are present or transmit/receive 
values are suspect.
Help Message
1
DTC
Fault Condition
(for configurable items,
fault applies only if
configured)
Fault
Requires
AccuPlace
Reset?
Action(s)