JLG G12-55A AccuPlace Service Manual User Manual
Page 129

9.11
G10-55A & G12-55A AccuPlace
Electrical System
b. UGM Outputs
J4-35
Left Stabilizer Joystick
Out of Neutral
Closed = V
bat
= Out of Neutral
J7-4
Aux Joystick Signal
Signal Range: 0.5 – 4.5V (2.5V = neutral)
0.5V = -100% = Aux1
4.5V = +100% = Aux2
J7-7
Sway Joystick Signal
Signal Range: 0.5 – 4.5V (2.5V = neutral)
0.5V = -100% = Sway Left
4.5V = +100% = Sway Right
J7-8
Left Stab Joystick Signal
Signal Range: 0.5 – 4.5V (2.5V = neutral)
0.5V = -100% = Left Down
4.5V = +100% = Left Up
J7-20
Right Stab Joystick
Signal
Signal Range: 0.5 – 4.5V (2.5V = neutral)
0.5V = -100% = Right Down
4.5V = +100% = Right Up
UGM
Connector/Pin
Description
Description/Purpose
UGM
Connector/Pin
Description
Description/Purpose
J1-2
Rear Stab Valve Signal 2
Current Capacity = 3A
Digital Output; Coil
Driver
J1-11
Circulation Valve
Current Capacity = 3A
Digital Output; Coil
Driver
J1-13
Rear Stab Valve Signal 1
Current Capacity = 3A
Digital Output; Coil
Driver
J2-8
Right Stabilizer Up Valve
Current Capacity = 3A
Proportional
Output; Coil Driver
J2-9
Left Stabilizer Up Valve
Current Capacity = 3A
Proportional
Output; Coil Driver
J2-11
Sway Left Valve
Current Capacity = 3A
Proportional
Output; Coil Driver
J2-19
Right Stabilizer Down Valve
Current Capacity = 3A
Proportional
Output; Coil Driver
J2-20
Left Stabilizer Down Valve
Current Capacity = 3A
Proportional
Output; Coil Driver
J2-22
Sway Right Valve
Current Capacity = 3A
Proportional
Output; Coil Driver
J4-26
Boom Ride Mode Lamp
Current Capacity = 350ma
Digital Output;
Lamp driver
J4-28
AccuPlace Mode Fault Reset Lamp
Current Capacity = 350ma
Digital Output;
Lamp driver
J4-29
AccuPlace Mode Lamp
Current Capacity = 350ma
Digital Output;
Lamp driver