JLG G12-55A AccuPlace Service Manual User Manual
Page 160

Electrical System
9.42
G10-55A & G12-55A AccuPlace
Max Right Stabilizer Up Duty Cycle
“RT STABILIZER UP MAX”
1300ma
1000-2000ma
Min Right Stabilizer Down Duty Cycle
“RT STABILIZER DN MIN”
600ma
400-1000ma
Max Right Stabilizer Down Duty Cycle
“RT STABILIZER DN MAX”
1300ma
1000-2000ma
Reduced left stabilizer function speed
“LT STABILIZER CREEP”
800ma
600-1400ma
Reduced right stabilizer function speed
“RT STABILIZER CREEP”
800ma
600-1400ma
SWAY JOYSTICK
Low Center Deadband Voltage (5V supply)
“DEADBAND LOW”
2.3V
1.90-2.50V
High Center Deadband Voltage (5V supply)
“DEADBAND HIGH”
2.7V
2.20-3.00V
Low End Voltage
(min command; 5V supply)
“MIN VOLTAGE”
0.5V
0.30-0.70V
High End Voltage
(max command; 5V supply)
“MAX VOLTAGE”
4.4V
4.00-4.60V
Low End Fault Voltage (5V supply)
“FAULT LOW”
0.25V
0.10-0.40V
High End Fault Voltage (5V supply)
“FAULT HIGH”
4.75V
4.40-4.90V
AUX JOYSTICK
Low Center Deadband Voltage (5V supply)
“DEADBAND LOW”
2.3V
1.90-2.50V
High Center Deadband Voltage (5V supply)
“DEADBAND HIGH”
2.7V
2.20-3.00V
Low End Voltage (min command; 5V supply)
“MIN VOLTAGE”
0.5V
0.30-0.70V
High End Voltage (max command; 5V
supply)
“MAX VOLTAGE”
4.4V
4.00-4.60V
Low End Fault Voltage (5V supply)
“FAULT LOW”
0.25V
0.10-0.40V
Function
Personality
Default Setting