9.41
G10-55A & G12-55A AccuPlace
Electrical System
9.15.3
Personality Settings
The following parameters are given to define how each
function shall perform when accessed. All parameters
can be viewed from Access Level 3, but can only be
modified in Access Level 2. Access Level 2 Code: 33271.
Function
Personality
Default Setting
Adjustment Range
FRAME SWAY
Acceleration
“ACCEL”
0.1 second
0.1-1.0 second
Deceleration
“DECEL”
0.1 second
0.1-0.5 second
Min Left Sway Duty Cycle
“MIN LEFT”
550ma
400-1000ma
Max Left Sway Duty Cycle
“MAX LEFT”
1700ma
1000-2000ma
Min Right Sway Duty Cycle
“MIN RIGHT”
550ma
400-1000ma
Max Right Sway Duty Cycle
“MAX RIGHT”
1700ma
1000-2000ma
Reduced sway function speed
“CREEP RT”
1000ma
600-1400ma
Reduced sway function speed
“CREEP LT”
1000ma
600-1400ma
STABILIZER
Left acceleration up
0.1 second
0.1-1.0 second
Left deceleration up
0.1 second
0.1-0.5 second
Right acceleration dn
0.1 second
0.1-1.0 second
Right deceleration dn
0.1 second
0.1-0.5 second
Min Left Stabilizer Up Duty Cycle
“LT STABILIZER UP MIN”
600ma
400-1000ma
Max Left Stabilizer Up Duty Cycle
“LT STABILIZER UP MAX”
1300ma
1000-2000ma
Min Left Stabilizer Down Duty Cycle
“LT STABILIZER DN MIN”
600ma
400-1000ma
Max Left Stabilizer Down Duty Cycle
“LT STABILIZER DN MAX”
1300ma
1000-2000ma
Min Right Stabilizer Up Duty Cycle
“RT STABILIZER UP MIN”
600ma
400-1000ma