JLG G12-55A AccuPlace Service Manual User Manual
Page 162

Electrical System
9.44
G10-55A & G12-55A AccuPlace
Deceleration down
“LIFT DN DECEL”
0.0500 kph
0.006-0.2 kph
Acceleration in
“TELE IN ACCEL”
0.0200 kph
0.01-1.0 kph
Deceleration in
“TELE IN DECEL”
0.0500 kph
0.02-1.0 kph
Acceleration out
“TELE OUT ACCEL”
0.0200 kph
0.01-1.0 kph
Deceleration out
“TELE OUT DECEL”
0.0500 kph
0.02-1.0 kph
Acceleration up
“FORK UP ACCEL”
1.000 kph
0.01-1.0 kph
Deceleration up
“FORK UP DECEL”
0.100 kph
0.02-1.0 kph
Acceleration down
“FORK DN ACCEL”
1.000 kph
0.01-1.0 kph
Deceleration down
“FORK DN DECEL”
0.100 kph
0.02-1.0 kph
Low Standard Speed
“LOW SPEED MLTPR”
0.400 0.2-0.5
Medium Speed
“MED SPEED MLTPR”
0.800 0.5-0.9
End of Stroke Slowdown Speed Multiplier (to
be used for all function soft stops)
“SOFT ZONE MLTPR”
0.400 0.2-0.9
Lift Up End of Stroke Slowdown Threshold
“LIFT UP SOFT ZN”
65.0 DEG
55.0-75.0 DEG
Lift Down End of Stroke Slowdown
Threshold
“LIFT DN SOFT ZN”
-2.0 DEG
-8.0 - (+2.0) DEG
Tele Out End of Stroke Slowdown Threshold
“TELE CYL OUT SFT ZONE”
11.48 FT
(3500mm)
10.16-12.13 FT
(3097-3697mm)
Tele In End of Stroke Slowdown Threshold
“TELE CYL IN SFT ZONE”
0.49FT
(150mm)
0-1.96FT
(0-597mm)
Function
Personality
Default Setting
Adjustment Range